Installing a Chassis
You turn on the switch when you connect its power supplies to one or two power sources.
Warning
Statement 1004 Installation Instructions
Read the installation instructions before using, installing or connecting the system to the power source.
Warning
Statement 1018 Supply Circuit
To reduce risk of electric shock and fire, take care when connecting units to the supply circuit so that wiring

is not overloaded.

Connecting a 3-kW AC Power Supply to an AC Power Source

Step 1

For each 3-kW AC power supply, connect an AC power cable to the AC power source and to the power receptacle on
the power supply.
Step 2
Verify that the Output Power LED turns on and becomes green.
What to do next
When the power supplies are operating and the switch is fully powered, you are ready to connect the switch
to the network.

Connecting a 3-kW Universal AC/DC Power Supply to an AC Power Source

The 3-kW Universal AC/DC power supply can be connected to either a 200-to-277-V AC circuit equipped
with a Saf-D-Grid receptacle. This procedure is for connecting the power supply to an AC power source.
Before you begin
The power switch on the power supply must be turned off (power switch set to 0).
Step 1
Verify that the power switch on the power supply is turned off (0).
Step 2
Connect the Saf-D-Grid connector on the AC power cable to the Saf-D-Grid receptacle for the AC power source.
Step 3
Connect the Saf-D-Grid connector on the other end of the power cable to the Saf-D-Grid receptacle on the power supply.
Step 4
Turn on the power supply by pressing its power switch to on (1).
Step 5
Verify that the Output Power LED turns on and becomes green.
sides for now and leave the middle slots open. Cover each open slot with a power supply slot blank to
preserve the designed airflow, until you add more power supplies.
Connecting a 3-kW AC Power Supply to an AC Power Source
Cisco Nexus 9516 ACI-Mode Switch Hardware Installation Guide
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nexus 9000 seriesC9516-fm-e-e2