Congratulations on purchasing this Siemens appliance. You
have acquired a top-quality product, which will give you a lot
of enjoyment.
Please read this installation and operating instruction
manual carefully, then act accordingly! Store for future
reference.

Installation instructions

Install the continuous-flow heater as described in the
illustrated section. Observe the instructions in the text.
The illustrations can be found in the centre of the instruction
manual.
Installation
Unpacking/Removing the cover
I.
Unpack the appliance and check for transport damage.
Please dispose of the packaging, and if applicable, the old
appliance in an environmentally-friendly manner.
Preparations for installation
II.
Important: Only use the supplied installation set.
The supplied water connection nozzles must be installed!
Shut off water supply. The electrical connection (connec-
tion cable) must be disconnected from the power supply.
Unscrew the fuse or switch off the circuit breaker.
III.
Wall mounting
The continuous-flow heater must be mounted on the
wall. Attach it if necessary on the lower adjustable screws.
The distance to the wall is variable. You can compensate
for any unevenness of the wall's surface.
The grommet must tightly surround the connection cable.
If it is damaged during mounting, the openings must be
provided with watertight sealing.
IV.
Water connection
The continuous-flow heater must be vented. Open
the warm water tap fully and flush out the appliance
thoroughly for 1 minute with at least 6 litres of water.
V.
Electrical connection/Mounting
The electrical supply terminal can be fitted at the top or
bottom. The sheath of the connection cable must extend
for at least 40 mm into the appliance.
Set the power using the power selector switch before
connecting the wires to the mains connection terminal:
Set DE 1113415 to 11 kW (down) or 13 kW (up).
Set DE 1821415 and DE 4151821 to 18 kW (down) or
21 kW (up).
Set DE 2427415 or DE 4152427 to 24 kW (down) or
27 kW (up).
10
en
The set power must be marked on the ratings plate.
Now screw the wires tightly into the mains connection
terminal.
Installation note
The installation of non plug-in ready appliances must be
undertaken by the respective utility operator or by a quali-
fied specialist company, who can also assist you when
you are requesting the approval of the utility company for
installation of the appliance.
Startup/additional information
VI.
The device is compliant to IEC 61000-3-12.
First start-up
Switch on the fuses.
Setting the temperature.
Starts rinsing: Open the warm water tap and allow water
to flow for at least 1 minute (flow-rate at least 6 litres per
minute). Only then (for safety reasons) will the appliance
begin to heat.
Tip: Should the appliance not start because of a reduced
flow-rate, remove the perlator, shower head or similar before
start and repeat the process.
Remove the flow-rate limiter (see Fig. A) with low water
pressure.
Explain the operation of the continuous-flow heater to
the user.
If the continuous-flow heater does not have sufficient
A
water flow due to low water line pressure in your do-
mestic plumbing system, remove the flow-rate limiter.
Priority circuit for the combination with electrical
B
storage heaters:
For operation with a priority circuit, a special load
shedding relay BZ 45L21 (special accessory) is re-
quired. Other existing load shedding relays, with the
exception of electronic load shedding relays, may
malfunction.
The control electronics must be coded when operated
C
with a load shedding relay.
Status display on the appliance
D
LED
Off
Lights up
Slow flash (1/s)
Fast flash (4/s)
Appliance status
Off
Ready
Appliance is heating
Desired water temperature
is not reached (water flow
too high for appliance
rating).