5. FUNCTIONS

5-1 Display

Part
Initializing
Refrigeraing
General run
Refrigeraing
Defrost
(forecooling+
heating+
time-delay)
Fast refrigeration
Fast freeze
Forced Startup
Forced Defrost

5-2 Constant Temperature Control

A.Freeze Temperature Control
1) You may control the freeze temperature by setting the freeze temerature from -15
at 1
interval.
2) Whenever you press the temperature control key, the temperature will display in the following
sequence: -18 ,-19 ,-20 ,-21 ,-22 ,-23 ,-15 ,-16 ,-17 ,-18 .
3) The freeze temperature is initialized as -18 .
Display the actual temparature. It will display the default temperature
when the refrigerating temperature falls into the setting range (+5,-3)
and when the freeze temperature falls into the setting range (+3,-3).
When the actual temperature is within the setting range (+5,-3), it will
display the default temperature. If the actual temperature exceeds the
setting vaule of +3, it will display the setting with flashes. if the actural
temperature is less than the setting value of -3, it will display the actual
temperature
When the actual temperature is within the setting range (+3,-3), it will
display the default temperature. If the actual temperature exceeds the
setting vaule of +3, it will display the setting with flashes. If the actual
Freeze
temparature reaches the setting value of -4, it will display the actual
temperature -1. if the actural temperature is less than the setting value
of -5, it will display the actual temperature -2.
During the defrost forecooling, when the actual temperature is within
the setting range (+5,-3), lock the current display till the first stop due
to compactor defrosting;
During the defrost heating, lock the current display till the first stop due
to compactor defrosting;
During the defrost forecooling, when the actual temperature is within
the setting range (+3,-3), lock the current display till the first stop due
to compactor defrosting;
Freeze
During the defrost heating, lock the current display till the first stop due
to compactor defrosting;
If the actual temperature is less than the setting of -3, it will display the
actual temperature;
Display FF (Forced Startup)
Display Fd (Forced Defrost)
Functions