2. Wiring Table for the TMS-6X
ROW 1
Loop/Ground Start
C.O. Lines
1T
1R
2T
2R
3T
3R
4T
4R
5T
5R
6T
6R
* Earth Ground
* Note: Earth Ground is only required in ground start applications.
Notes: If the PABX does not recognize lines on the TMS-6X as busy and call crashing is observed, set up those lines as "incoming only trunks" on the PABX. If those lines
must be used for inbound and outbound calls, you must use the special software TMX-PRAL. Contact Viking product support at (715) 386-8666 for more information. Do not
install bridging clips on any connections which connect the two halves of the punch down terminal block. Bridge clips should only be installed as a method of bypassing equip-
ment. In order for the SQRG-12 to work properly, the four-wire modular jack must be installed between the TMS CONTROL LINE on the SQRG-12 and the SQRG jack on the
TMS-6X or TMS-12A.
B. Installing the SQRG-12 with the TMS-12A
1. Wiring
Loop Start TMS-12A DIP Switches
DIP Switch
2
3
11
Ground Start TMS-12A DIP Switches
DIP Switch
2
3
11
2. Wiring Table for the TMS-12A
ROW 1
Loop/Ground Start
C.O. Lines
1T
1R
2T
2R
3T
3R
4T
4R
5T
5R
6T
6R
7T
7R
8T
8R
9T
9R
10T
10R
11T
11R
12T
12R
* Earth Ground
ROW 2
ROW 3
ROW 4
TMS-6X
SQRG-12
Open
Pin, Color
26, W/BL
L1, G
1, BL/W
L1, R
27, W/O
L2, BK
2, O/W
L2, Y
28, W/G
L3, W
3, G/W
L3, BL
29, W/BN
L4, G
4, BN/W
L4, R
30, W/S
L5, BK
5, S/W
L5, Y
31, R/BL
L6, W
6, BL/R
L6, BL
50, V/S
Rear View of the TMS-12A
SQRG-12
WARBLE
TMS-RDMA
TMS-RDMA
POWER
VOLUME
INPUTS / OUTPUTS
13.8VAC
MUSIC
Position
UP
DOWN
UP
Position
DOWN
UP
UP
ROW 2
ROW 3
ROW 4
TMS-12A
SQRG-12
Open
Pin, Color
Pin, Color
26, W/BL
26, W/BL
1, BL/W
1, BL/W
27, W/O
27, W/O
2, O/W
2, O/W
28, W/G
28, W/G
3, G/W
3, G/W
29, W/BN
29, W/BN
4, BN/W
4, BN/W
30, W/S
30, W/S
5, S/W
5, S/W
31, R/BL
31, R/BL
6, BL/R
6, BL/R
32, R/O
32, R/O
7, O/R
7, O/R
33, R/G
33, R/G
8, G/R
8, G/R
34, R/BN
34, R/BN
9, BN/R
9, BN/R
35, R/S
35, R/S
10, S/R
10, S/R
36, BK/BL
36, BK/BL
11, BL/BK
11, BL/BK
37, BK/O
37, BK/O
12, O/BK
12, O/BK
44, Y/BN
50, V/S
ROW 5
ROW 6
SQRG-12
Loop/Ground Start
Pin, Color
C.O. Lines
38, BK/G
1T
13, G/BK
1R
39, BK/BN
2T
14, BN/BK
2R
40, BK/S
3T
15, S/BK
3R
41, Y/BL
4T
16, BL/Y
4R
42, Y/O
5T
17, O/Y
5R
43, Y/G
6T
18, G/Y
6R
Ground Start or
Ring All Lines
Loop Start
Viking Electronics, Inc.
Hudson, WI 54016
ON
9 10 11 12
RJ21X Male Jack
(not included)
1-12 C.O. Lines
Punchdown
Terminal
Block with
Split Center
(not included)
Siemans
# 566B3-50
Marconi
# R66B3-50
ROW 5
ROW 6
SQRG-12
Loop/Ground Start
Pin, Color
C.O. Lines
38, BK/G
1T
13, G/BK
1R
39, BK/BN
2T
14, BN/BK
2R
40, BK/S
3T
15, S/BK
3R
41, Y/BL
4T
16, BL/Y
4R
42, Y/O
5T
17, O/Y
5R
43, Y/G
6T
18, G/Y
6R
44, Y/BN
7T
19, BN/Y
7R
45, Y/S
8T
20, S/Y
8R
46, V/BL
9T
21, BL/V
9R
47, V/O
10T
22, O/V
10R
48, V/G
11T
23, G/V
11R
49, V/BN
12T
24, BN/V
12R
Rear View of the SQRG-12
Note: For proper ground
start operation, DIP switches
1-12 must be set to OFF as
shown above.
J2
J2
SEQUENTIAL RING
GENERATOR
VIKING
MODEL SQRG-12
RJ21X
RJ21X
1 2 3 4
ON
POWER
1 2 3 4
VIKING ELECTRONICS INC. HUDSON, WI 54016
(V/S)
Earth Ground
Note: Earth ground is required
in ground start applications.
Trunk Inputs
of PABX/KSU
Rear View of the SQRG-12
Note: For proper ground
start operation, DIP switches
1-12 must be set to OFF as
shown above.
* Note: Earth Ground is only required in ground
start or master / slave applications.
12
11
10
9
8
7
6
5
4
3
2
1
ON OFF
RESET
TMS
CONTROL LINE
©
13.8V AC
1.25A MAX
DIP
Switches
ON
ON
OFF
1 2 3 4
13.8V AC
Adapter
(included)
12
11
10
9
8
7
6
5
4
3
2
1
ON OFF

Advertisement