Wall Shields
Wall shields should be constructed of 24 gauge or
heavier sheet metal, or another noncombustible mate-
rial such as 1/2" (13mm) insulation board or common
brick "laid on flat," with the 3¹⁄₂" (90mm) side down.
Shields must be spaced out from the combustible sur-
face 1" (25mm) on noncombustible spacers. The spac-
ers should not be directly behind the stove or chimney
connector.
Air must be able to flow between the wall and the
shield. At least 50% of the bottom 1" (25mm) of the
shield should be open and the shield must be open at
the top.
Air flow
Stud wall
framing
Wall shield
Noncombus-
tible spacers
and fasteners
Drywall
Air flow
Fig. 16 Approved Wall shield construction
The following examples of wall shield construction illus-
ST248
trate common designs used to safely achieve reduced
wall shield construction
12/14/99 djt
clearances to combustible wall materials.
Parallel installation, vertical chimney connector,
two wall shields. Fig. 17: Reduced clearances for
both rear and side walls. Wall shields may meet at
corner if desired. Shielding for connector is centered
behind connector.
Parallel installation with rear wall pass-through, two
wall shields. Fig. 18: Reduced clearances for both
rear and side walls. Wall shields may meet at corner
if desired. Shielding for connector is centered behind
connector. Wall pass-through must comply with codes.
Corner installation, vertical chimney connector, two
wall shields. Fig. 19: Reduced side clearances. Wall
shields MUST meet at corner.
30000369
Screen
Shield
Metal Spacer
ST248
36"
(914mm)
40"
(1016mm)
1"
(25mm)
Fig. 17 Parallel installation, vertical chimney connector, two
wall shields.
36"
(914mm)
41"
(1016mm)
1"
(25mm)
Fig. 18 Parallel installation with rear wall pass-through, two
wall shields.
ST250
parallel rear wall
12/14/99 djt
36"
(914mm)
40"
(1020mm)
1"
(25mm)
Fig. 19 Corner installation, vertical chimney connector, two
wall shields.
Aspen Woodburning Stove
36"
(914mm)
40"
(1016mm)
1 "
( 2 5 m m )
ST249
parallel vertical wall shield
12/14/99 djt
13"
(330mm)
41"
(1016mm)
1 "
( 2 5 m m )
36"
(914mm)
40"
(1020mm)
1 "
( 2 5 m m )
ST251a
corner install
vertical
12/14/99 djt
ST249a
ST250a
ST251a
11