Irving IRFSDV24 Installation Instructions And Homeowner's Manual

Oil fireplace freestanding direct vent fireplaces

Advertisement

Quick Links

INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY
OR LOSS OF LIFE.
FOR YOUR SAFETY
Installation and service must
be performed by a qualified in-
staller, service agency or
the gas supplier.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from your neighbor's phone. Follow
the gas suppliers instructions.
• If you cannot reach your gas
supplier call the fire department.
DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE.
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
10004000
Freestanding
Direct Vent
Fireplaces
IRFSDV24
IRFSDV34
Installation Instructions and
Homeowner's Manual
The VermontCastings,
Majestic Products Company
410 Admiral Blvd. Mississauga,
Ontario, Canada. L5T2N6
www.majesticproducts.com / www.vermontcastings.com
Irving Oil
10004000
0102 Rev. 0
1

Advertisement

Table of Contents
loading

Summary of Contents for Irving IRFSDV24

  • Page 1 LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER 10004000 Freestanding Direct Vent Fireplaces IRFSDV24 IRFSDV34 Installation Instructions and Homeowner’s Manual The VermontCastings, Majestic Products Company 410 Admiral Blvd. Mississauga, Ontario, Canada.
  • Page 2: Table Of Contents

    Irving Oil THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Irving Oil fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation Instructions ...
  • Page 3: Installation Instructions

    INSTALLATION & OPERATING INSTRUCTIONS This gas fireplace should be installed by a qualified installer in accordance with local building codes and with current CSA-B149 (.1 or .2) Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code.
  • Page 4: Fireplace Dimensions

    Irving Oil IRFSDV24 23 in (584 mm) 28-3/4 in (730 mm) 16-5/8 in (422 mm) 27-3/8 in (695 mm) 9-1/2 in (241 mm) 13-7/8 in (352 mm) 4 in (102 mm) 23 in (584 mm) 11-1/2 in (292 mm) 16-5/8 in (422 mm) 6”...
  • Page 5: Gas Specifications

    In Canada, please consult provincial and/or local authorities having jurisdiction for install- ations at elevations above 4,500 feet (1,370 m). CFM186 IRFSDV24/IRFSDV34 CERTIFIED TO ANSI Z21.88b-1999 / CSA 2.33b-M99 Vented Gas Fireplace Heaters GAS INLET AND MANIFOLD PRESSURES...
  • Page 6: Installation Of Remote Switch For Rn/Rp Gas Valve

    Irving Oil When using copper or flex connector use only ap- proved fittings. Always provide a union when using black iron pipe so that gas line can be easily disconnected for burner or fan servicing (see Fig. 2) See gas specification for pressure details and ratings. The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi.
  • Page 7: General Venting Information

    GENERAL VENTING INFORMATION–TERMINATION LOCATION VENT TERMINATION CFM145a A = Clearance above grade, veranda, porch, deck, or balcony B = Clearance to window/door that may be opened C = Clearance to permanently closed window D = Vertical clearance to ventilated soffit located above the terminal within a hori- zontal distance of 2 feet (610mm) from the center line of the terminal...
  • Page 8: Termination Clearance

    Irving Oil Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Combustible 6"(152mm) Noncombustible 2"(50mm) Fig. 6 Balcony - with no side wall Combustible 24"(610mm) Non-Combustible 18"(457mm) Fig. 8 Outside Corner Combustible 6"(152mm) Noncombustible 2"(50mm) Fig. 7 Balcony - with perpendicular side wall Combustible &...
  • Page 9: General Information On Assembling Vent Pipes

    GENERAL INFORMATION ON ASSEMBLING THE VENT PIPES IN DIRECT VENT APPLICATIONS NOTE: Only venting components manufactured by The Vermont Castings Majestic Products Company may be used. CRIMPED END PIPES Before joining elbows and pipes apply a bead of high temperature sealant to the crimped end of the elbow or pipe.
  • Page 10: Vertical Sidewall Installations

    VERTICAL SIDEWALL APPLICATIONS • The maximum number of 90 elbows per side wall installations is three (3). • For IRFSDV24 and IRFSDV34 models the maximum horizontal run off a minimum 12” vertical rise is 3’ (see Fig. 15). • If a 90˚ elbow is used in the horizontal vent run (level height maintained) the maximum horizontal vent length is reduced by 36 inches, (Fig.
  • Page 11: Sidewall Venting Graph

    TO USE THE VENT GRAPH 1. Determine the height of the center of the horizontal vent pipe exiting through the outer wall. Using this dimension on the Sidewall Vent Graph below, locate the point it intersects with the slanted graph line. 2.
  • Page 12: Vent Pipe Assembly

    Irving Oil VENT PIPE ASSEMBLY STEP 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size (Fig. 17). (For combustible walls first frame in opening.
  • Page 13: Below Grade Installations (Snorkel)

    STEP 5 Measure the horizontal length requirement including a 2” (50 mm) overlap, i.e. from the elbow to the outside wall face plus 2” (or the distance required if installing a second 90 elbow (Fig. 21). Always install horizontal venting on a level plane.
  • Page 14: Vertical Through-The-Roof Applications

    Irving Oil If installing a snorkel a minimum 24” vertical rise is necessary. The maximum horizontal run with the 24” vertical pipe is 36” (915 mm). This measurement is taken from the collar of the fireplace to the face of the exterior wall.
  • Page 15 installations. From 0 to a maximum of 8’ of vent pipe can be used between elbows (Fig. 25). • 7DVCS must be used to support offsets (Fig. 26). This application will require that you first determine the roof pitch and use the appropriate starter kit.
  • Page 16: Venting Components

    Irving Oil CRIMPED END VENTING COMPONENTS Starter Kit-Model 7FSDVSK-Sidewall Venting Starter Kit-Model 7TDVSKV-Vertical Venting for 7DVSKV-A order 1/12 to 6/12 roof pitch for 7DVSKV-B order 7/12 to 12/12 roof pitch for 7DVSKV-F order flat roof Starter Kit-Model 7FSDVSKS-Snorkel Kit for Below Grade Installation 45˚...
  • Page 17: Twist Lock

    TWIST LOCK VENTING COMPONENTS 10004000 Starter Kit - Model 7TFSMSK Starter Kit-Model 7TFSDVSK-Sidewall Venting Starter Kit-Model 7TDVSKV - Vertical Venting for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDVSK-F order flat roof Starter Kit-Model 7TFSDVSKS-Snorkel Kit for Below Grade Installation 45˚...
  • Page 18: Operating Instructions

    Irving Oil GENERAL GLASS INFORMATION Only glass approved by the Vermont Castings, Majestic Products Company may be used for replacement. • The use of substitute glass will void all pro- duct warranties. • Care must be taken to avoid breakage of the glass. Under no circumstances should this fireplace be operated without the front glass or with a broken glass.
  • Page 19: Maintenance

    INSTALLATION OF LOGS & BURNER LAVA ROCK MATERIAL ( Model: IRFSDV24 Refer Figure 33. 1. Remove window frame assembly (See Window Frame Assembly section). 2. Remove logs from packaging. As with all plastic - these are not toys and should be kept away from children and infants.
  • Page 20: Fan Fk24

    Fig. below. A: SPEED CONTROL B: TEMPERATURE SENSOR C: FAN Black White Ground IRFSDV24 IRFSDV34 FAN - FK24 This fan assembly comes completely wired to eliminate the need for elec- tricians. This electrical device must be electrically connected and grounded in accordance with local codes.
  • Page 21: Optional Remote Control

    REMOTE CONTROLS These remote controls are available as an option only on fireplaces fitted with RN/RP gas control valves. IRFSDV24 model only. MRC1 On/Off Button Remote Control MRC2 Temperature Control Remote MRC3 Temperature Control w/digital display & 24 hour program-...
  • Page 22: Lighting Instructions

    Irving Oil LIGHTING AND OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This fireplace has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly.
  • Page 23: Rfn/Rfp Remote Control Instructions

    OPERATING INSTRUCTIONS FOR RFN/RFP COMFORT CONTROL VALVE The Comfort Control Valve allows remote control of temperature, fan and flame appearance. NOTE: The antenna should hang in free air away from grounded metal. OPERATION 1. If the manual switch is in remote position, switch it to LOCAL.
  • Page 24: Troubleshooting

    Irving Oil Delay Timer Mode The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes. Auto Mode In the AUTO mode, the room temperature, set tem- perature, flame and fan levels will be shown.
  • Page 25: Trouble Shooting The Gas Control System

    TROUBLE SHOOTING THE GAS CONTROL SYSTEM Comfort Valve system control sequence of operation with transmitter Set manual switch to local or remote Light pilot burner Did the LED stop Review LED blinking? failure analysis Release pilotstat knob Cycle switch once and Turn pilotstat knob leave in remote.
  • Page 26: Replacement Parts

    Electrode igniter with cable 24” Valve, Honeywell Radio Frequency - Nat Valve, Honeywell Radio Frequency - Prop Valve, Honeywell, RN Valve, Honeywell, RP Electric Cord Set. Radio Frequency Valve REPLACEMENT PARTS LIST IRFSDV24 10003538 KR13 KR14 — — — KR15...
  • Page 27 Plate Relief with Gasket Assembly Front Grate Assembly - Charcoal Gray Sensor Fan Speed Control Thermocouple SIT Note: Items marked ‘*’are not shown in the following parts pictorial. 10004000 REPLACEMENT PARTS LIST IRFSDV24 54103 53606 57265 53859 10003973 10003974 10001983...
  • Page 28: Replacement Parts Pictorial

    Irving Oil IRFSDV24 Log Set REPLACEMENT PARTS 9c/d 8a/b 18a/b 9a/b IRFSDV34 Log Set 10004000 18c/d...

This manual is also suitable for:

Irfsdv34