Remove Glass Doors Before Service Work
START
GAS SUPPLY ON
YES
PILOT LIGHTS WITH
PIEZO IGNITOR
YES
PILOT STAYS LIT
YES
PILOT LIGHTS MAIN
BURNER
YES
SYSTEM OK
10004798
Troubleshooting – Honeywell VS8421
CHECK
NO
Supply Line Hooked Up
Shutoff Valve Open
Lockout Has Engaged. Wait 60
Seconds And Try Again.
For Spark At Electrode While
Depressing Piezo
NO
1/8" Gap To Pilot Hood Needed.
All Wiring Connections
Replace Piezo Ignitor
For Air In The Lines
Thermopile Needs A Min.
325mv. Adjust Pilot Flame
Height.
All Wiring Connections
NO
Replace Thermopile
Thermocouple Needs A Min. Of
14mv
Defective Valve. Turn To Pilot,
Meter Should Read Greater
Than 100mv. If Not, Replace.
Valve Is Turned On
Wall Switch Is Not Turned On.
Watch For Grounded Wires!
NO
Thermopile Needs A Min. 325mv.
Plugged Burner Orifice
Pyromaster
H33BDVRRN/P
©
23