Pentair EVERPURE CONSERV 75E EV9977-00 Original Instructions Manual

Reverse osmosis (ro) system

Advertisement

EVERPURE
CONSERV
®
INTRODUCTION
The Everpure Conserv 75E System is a pre-engineered, pre-assembled solution designed to provide high purity water for
non-steam applications. It combines a number of water treatment technologies into one easy-to-install package. The system
provides reduction of sediment. It also limits corrosion* and scale* by reducing TDS, chlorine* and chloramines*.
INSPECTION
Before mounting the Conserv 75E System, inspect the parts. Use the table and illustration provided to verify the parts and
quantities provided. If any parts are missing, contact Customer Service at 800.942.1153 (US only)/630.307.3000 or by email at
CSeverpure@pentair.com.
Parts
1. Back Panel Assembly
2. GRO-75EN RO Membrane Cartridge
3. 4CC Mineral Cartridge
4. 4FC5-S Filter Cartridge
5. Cover
6. 4CB5 Filter Cartridge
7. TDS Meter
8. Support Leg
9. Power Cord
10. Blue, White and Red Tubing
* Not performance tested or certified by NSF
FOODSERVICE
EVERPURE
ORIGINAL INSTRUCTIONS
75E HIGH EFFICIENCY REVERSE OSMOSIS (RO) SYSTEM
®
Conserv 75E
EV9977-00 (US Market)
EV9977-01 (European Market)
EV9977-02 (British Market)
EV9977-03 (Australian Market)
2
3
5
®
CONSERV
75E HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE
®
®
4
6
9
7
1
8
10

Advertisement

Table of Contents
loading

Summary of Contents for Pentair EVERPURE CONSERV 75E EV9977-00

  • Page 1 Before mounting the Conserv 75E System, inspect the parts. Use the table and illustration provided to verify the parts and quantities provided. If any parts are missing, contact Customer Service at 800.942.1153 (US only)/630.307.3000 or by email at CSeverpure@pentair.com. Parts 1.
  • Page 2: Selecting A Mounting Location

    Tools Required OPERATING SPECIFICATIONS WARNING: Before installing the system, make certain your water supply complies with the • Hand or Electric Drill • Phillips Screwdriver following operating specifications. Failure • Air Pressure Gauge • Towel to do so may reduce the effectiveness of •...
  • Page 3 WARNING: This appliance must be grounded. This WARNING: The Conserv 75E System shall only be appliance is equipped with a cord having used for arsenic reduction on chlorinated an appliance-grounding conductor and water supplies containing detectable a grounding plug. The plug must be residual free chlorine at the system plugged into an appropriate outlet that inlet.
  • Page 4 EVERPURE CONSERV 75E SYSTEM ® ® Secure Manifold Wall Mount Tubing Locations Filtered Water 3/8" Tubing to the Application Power Cord Accessory Tank 3/8" Connection 58 lbs (26 kgs) Blended RO Water 3/8" Tubing to the Application NOTE: Feet may be removed. Waste Water 1/4"...
  • Page 5 Install Pentair GRO-75EN RO Membrane Cartridge ® White GRO-75EN Blue Install Everpure 4CC Mineral Filter, 4CB5 Filter and 4FC5-S Filter Cartridges 3/16” 90° EVERPURE CONSERV 75E HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE ® ®...
  • Page 6 Connect Tubing and Power Power Cord Filtered Water Accessory Tank Blue 3/8" 3/8" Tubing Connection Tubing to 3/8" Tubing Application Valve NOTE: Maximum 6 gal (22.7L) Red 1/4" Accumulator tank size. Set White 3/8" Tubing Tubing to recharge to 25 psi (1.72 bar, from Water Supply Drain 0.17 MPa...
  • Page 7 Flush GRO-75EN RO Membrane Cartridge Open Tank Valve Power On Power Off Open Closed Insert 3/8" Tubing Closed Open Flush for 24 Hours Final Flush Power On Close for 30 Open Minutes When Pump Stops, Open for Five (5) Minutes. Repeat Four (4) Times NOTE: During the final flush, the storage tank and the 4CC Mineral Cartridge are flushed.
  • Page 8 Set Blending Valve Power Open Open Blending Valve Closed Press 1/4 Turn Solid Blue Blending Valve 2" Press 1/4 Turn Solid Blue Blending Valve 2" 1/8 Turn Flashing Blue Repeat Until Blending Valve EVERPURE CONSERV 75E HIGH EFFICIENCY RO SYSTEM INSTALLATION AND OPERATION GUIDE ®...
  • Page 9: Installation

    RO membrane cartridge of the 3. Tighten both screws from the front with the cover Conserv 75E System should last 12 to 24 months. removed. The precise life span of the Pentair GRO-75EN RO ® Mounting Screw Slots...
  • Page 10: Installing The Cartridges

    The cartridges are identified on the label using the model number. 3. Locate an appropriate point in the hard water plumbing to tie in a new section of tubing/piping that can be routed Pentair GRO-75EN RO Membrane Cartridge ® to the RO system. CLOSE the nearest shut-off valve...
  • Page 11 Install the Everpure 4FC5-S Filter Cartridge Install the Pentair GRO-75EN RO Membrane Cartridge Locate the 4FC5-S Filter Cartridge and inspect the o-rings. They should be clean and lightly lubricated with silicone The GRO-75EN RO Membrane Cartridge is installed in the grease.
  • Page 12: Putting The System Into Operation

    Flush the Everpure 4FC5-S Filter Cartridge Install the Everpure 4CB5 Filter Cartridge Locate the 4CB5 Filter Cartridge and inspect the o-rings. Flush Port for They should be clean and lightly lubricated with silicone Tank Valve 4FC5-S Cartridge grease. 1. Line up the tabs with the slots in the opening on the front Electrical right side of the head assembly.
  • Page 13 CAUTION: Visually check the entire system for leaks. If a Flush the Pentair GRO-75EN RO Membrane leak is present, see Troubleshooting. ® Cartridge NOTE: Initially, the water may appear cloudy. This is a result Tank Valve of air trapped in the postfilter cartridge. It is not harmful and will disappear in a matter of minutes.
  • Page 14: Replacement Cartridges

    To achieve the target TDS of 75 ppm, it is likely that the blend Everpure 4CC Mineral Cartridge - EV9627-45 valve will need to be opened. Pentair GRO-75EN RO Membrane Cartridge - 4002575 ® The desired reading of 75 ppm is at the high end of the solid blue range.
  • Page 15 Push the top tubing into the the Pentair Everpure 2JT Cartridge (EV9608-10). connector at the top of the cartridge. CAUTION: DO NOT install the Pentair GRO-75EN RO NOTE: The bottom of the GRO-75EN RO Membrane Cartridge Membrane Cartridge for the sanitization will be supported by the lower bracket.
  • Page 16: Troubleshooting

    26. CLOSE the water supply valve and OPEN the application CAUTION: The 1/4" red tubing connected to the bottom valve to remove pressure. drain connection of the RO cartridge has a flow 27. Remove the tubing that connects the Pentair GRO-75EN ® restrictor installed. The system will not operate RO Membrane Cartridge white (top) and blue (bottom) correctly if the restrictor is removed.
  • Page 17 Sudden Return of Taste and Odor 3. Tubing should be cut squarely. Internal and external burrs should be removed. Place a mark on tubing 5/8" If shortly after complete servicing, noticeable taste and odors (1.6 cm) from end on 1/4" tubing or 3/4" (1.0 cm) from return, contact Technical Support.
  • Page 18: Replacement Parts

    REPLACEMENT PARTS Contact your local Pentair Everpure Dealer for filter ® cartridges or system replacement parts. Description Part Number GRO-75EN RO Membrane Cartridge 4002575 4FC5-S Filter Cartridge EV9693-31 4CC Mineral Cartridge EV9627-45 4CB5 Filter Cartridge EV9617-11 Storage Tank EV3146-55 TDS Meter...
  • Page 19: Limited Warranty

    COMMERCIAL WATER TREATMENT EQUIPMENT You have just purchased one of the finest water treatment units made. As an expression of confidence in this product, Pentair Filtration You have just purchased one of the finest water treatment units made. As an expression of confidence in this product, Pentair Filtration Solutions, LLC (“PFS”) offers the following product warranty.
  • Page 20 65.6768.5800 TEL • 65.6737.5149 FAX • CSEVERPURE@PENTAIR.COM EMAIL Pentair trademarks and logos are owned by Pentair plc or its affiliates. Third party registered and unregistered trademarks and logos are property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.

Table of Contents