Leakage Current Hot Check (See Figure 1 .) - Panasonic DMR-E53EG Service Manual

Hide thumbs Also See for DMR-E53EG:
Table of Contents

Advertisement

1.1.2 Leakage current hot check
(See
Figure 1
TOP PREVIOUS NEXT
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5kΩ, 10 watts resistor, in parallel with a 0.15μF capacitors, between each exposed
metallic part on the set and a good earth ground such as a water pipe, as shown in
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across
the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson
Model 229 or equivalent) may be used to make the hot checks, leakage current must not exceed
1/2 milliampere. In case a measurement isoutside of the limits specified, there is a possibility of a
shock hazard, and the equipment should be repaired and rechecked before it is returned to the
customer.