INSTALLATION, OPERATION AND
M A I N T E N A N C E I N ST R U CT I O N S
Hybrid Air Terminal
36XB
Translation of original document

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 36XB

  • Page 1 INSTALLATION, OPERATION AND M A I N T E N A N C E I N ST R U CT I O N S Hybrid Air Terminal 36XB Translation of original document...
  • Page 2: Table Of Contents

    Contents 1 - PReCAUtIons ................................................7 1.1 - Operating limits ..............................................1.2 - Maintenance requirements ........................................... 1.3 - Delivery ................................................... 1.4 - Storage ..................................................1.5 - Supply voltage 230 V ± 10% - 50 Hz ........................................2 - sAFetY ConsIDeRAtIons ............................................ 7 2.1 - General ..................................................
  • Page 3 60 cm 60 cm...
  • Page 6 Figure titles and key: Clearances for maintenance Grille opening position "Electrical hazard" pictogram "Danger to hands" pictogram "General danger" pictogram Safety device (to prevent the grille falling) Lifting and installation in the suspended ceiling Connecting multiple units to the same drainage manifold Condensate drain pipe Siphon (height greater than 50mm) 10 Procedure for opening the grille...
  • Page 7: Precautions

    Carrier recommends that the supply air temperature is kept below 35°C in order to avoid the risk of stratification. Note: The grille must only be opened with the Carrier tool specially provided: Fig.10 and 11. 1.1.3 - Operating environment...
  • Page 8: Protection Against Electrocution

    They also comply with the low-voltage directive. IMPORTANT: It is not permitted to connect several 36XB units to the same control device (wall thermostat, 2.3 - General recommendations for installation electronic NTC, etc.). IMPORTANT: controllers must have a disconnection 2.5 - Conformity...
  • Page 9: Installation Procedure

    ATTENTION: All valves and components connected to the unit on which condensation may form must be • Place the 36XB on the ground, in the location where it insulated (not supplied by Carrier). is to be installed in the suspended ceiling. For...
  • Page 10: Water Coil

    4.6 - Fresh air flow controller option Left-hand connections: Fig 17a Right-hand connections: Fig 17b. The 36XB Hybrid Air terminal can be equipped (as an ATTENTION: Ensure the flow direction indicated by an option) with a fresh air flow controller with a variable flow rate from 0 to 41.6 l/s (0 to 150 m...
  • Page 11: Water Flow Control Valves Option

    4.7.1 - Valve actuator ensuring that all the gaskets have been replaced and refitted (tightening torque: 20 Nm). Carrier offers several types of actuator as a standard or • Check that the water purge for the coil is in the closed special option: On/Off 230 VAC.
  • Page 12 No.10005, 09.2014 - Replace No.: New. Printed in the European Union. The manufacturer reserves the right to change the product specifications without notice.