THANK YOU for purchasing this combination alarm. It is designed to detect carbon monoxide and
natural gas (methane) which reaches the sensor. It is not designed to detect fire, heat, flames or any
other gas. This manual includes important information regarding where to install the alarm, how to
operate, maintenance, testing and product features. It also includes tips and information which
could help protect you and your family.
What You Should Know About CO .......................................... 2
What You Should Know About Natural Gas ............................ 2
Basic Safety Information ......................................................... 3
Recommended Location of Alarms ......................................... 4
Avoid These Locations ........................................................... 4
How to Install .......................................................................... 5
Operation & Alarm Characteristics .......................................... 6
What To Do If The Alarm Sounds ........................................... 7
Silence Feature ...................................................................... 7
Testing & Maintenance ........................................................... 8
Battery Replacement .............................................................. 8
CO & Natural Gas Alarm Limitations ....................................... 9
Operational Summary ........................................................... 11
Warranty ................................................................. Back Cover
MODEL MCN400CN, MCN400LCN
MODEL MCND401CN, MCND401LCN
(WITH DISPLAY)
PLUG-IN CARBON MONOXIDE AND
NATURAL GAS ALARM WITH BATTERY
BACKUP AND SILENCE FEATURE
MODEL MCN600CN, MCN600LCN
MODEL MCND601CN, MCND601LCN
(WITH DISPLAY)
PLUG-IN CARBON MONOXIDE AND
NATURAL GAS ALARM WITH BATTERY
BACKUP AND SILENCE FEATURE
PLEASE READ AND SAVE!

Table of Contents:

Cert. to Std
CSA 6.19-01
Page #

Advertisement

Table of Contents
loading

Summary of Contents for Universal Security Instruments MCN400CN

  • Page 1: Table Of Contents

    Testing & Maintenance ... 8 Battery Replacement ... 8 CO & Natural Gas Alarm Limitations ... 9 Operational Summary ... 11 Warranty ... Back Cover MODEL MCN400CN, MCN400LCN MODEL MCND401CN, MCND401LCN (WITH DISPLAY) PLUG-IN CARBON MONOXIDE AND NATURAL GAS ALARM WITH BATTERY...
  • Page 2: What You Should Know About Co

    WHAT YOU SHOULD KNOW ABOUT CO Carbon monoxide (CO) is an insidious poison. It is a colorless, odorless, tasteless gas. It is a cumulative poison. Even low levels of CO have been shown to cause brain and other vital organ damage in unborn infants with no effect on the mother.
  • Page 3: Basic Safety Information

    In general, install combination CO and Gas Alarms: • WHERE YOU CAN HEAR THE ALARM FROM ALL SLEEPING AREAS. • In or near bedrooms and living areas or wherever you suspect a gas or CO exposure is likely. • On each level of a multilevel home. IMPORTANT! Installation in an improper location can affect the sensitive electronic components in this alarm.
  • Page 4: Recommended Location Of Alarms

    RECOMMENDED PLACEMENT: NOTE: For any location, make sure no door or other obstruction could prevent the carbon monoxide or gas from reaching the alarm. WHERE THIS ALARM SHOULD NOT BE INSTALLED To avoid causing damage to the unit, to provide optimum protection, and to prevent unnecessary alarms.
  • Page 5: How To Install

    • Good ventilation is recommended when household cleaning supplies or similar contaminants are used. • Excessive spillage or reverse venting of fuel-burning appliances caused by outdoor ambient conditions, such as: Wind direction and/or velocity, including high gusts of wind. Heavy air in the vent pipes (cold/ ...
  • Page 6: Operation & Alarm Characteristics

    IMPORTANT! The battery backup is designed to provide short-term emergency power to the CO and Gas Alarm. Actual backup time depends on the strength (freshness) of the battery. The battery backup will not work unless a good battery is properly installed. When the alarm utilizes battery backup power, the natural gas sensor will operate the alarm and will sample less frequently to extend battery life.
  • Page 7: What To Do If The Alarm Sounds

    IF THE CO ALARM SOUNDS: Operate SILENCE button; Call your emergency services, fire department or 911. Write down the number of your local emergency service here: Immediately move to fresh air - outdoors or by an open door/window. Do a head count to check that all persons are accounted for.
  • Page 8: Testing & Maintenance

    WEEKLY TESTING • NEVER use an open flame of any kind to test this unit. You might accidentally damage or set fire to the alarm or to your home. The built-in test switch accurately tests the unit's operation as required by CSA 6.19-01 Standard. NEVER use vehicle exhaust! Exhaust may cause permanent damage and voids your warranty.
  • Page 9: Co & Natural Gas Alarm Limitations

    Use only the batteries specified. Use of different batteries may have a detrimental effect on the CO/Gas alarm. The constant exposures to high or low temperatures or high humidity may reduce battery life. IMPORTANT! The battery backup is designed to provide short-term emergency power to the alarm. Actual backup time depends on the strength (freshness) of the battery.
  • Page 10 HOW CAN I PROTECT MY FAMILY FROM CO POISONING? This alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before carbon monoxide levels become threatening to the average, healthy adult. An alarm is not a substitute for proper maintenance of home appliances. To help prevent CO problems and reduce the risk of CO poisoning: Clean chimneys and flues yearly.
  • Page 11: Operational Summary

    CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS BEFORE SOLUTION / RECOMMENDATION POWER HORN GREEN LED Silent On and Blinks off approx every 20 seconds Silent Off and Blinks on approx every 40 seconds 1 beep, Turns off 1 second when the pause, 4 beeps start 4 beeps,...
  • Page 12: Warranty

    MODELS MCN400CN, MCN400LCN, MCN600CN, MCN600LCN MODELS MCND401 CN, MCND401L CN, MCND601 CN, MCND601L CN USI ELECTRIC, INC./UNIVERSAL SECURITY INSTRUMENTS, INC. ("USI") warrants your USI product to be free from defects in material and workmanship for a period of five (5) years from the date of purchase. This warranty shall not apply to any batteries used in the product or to any damage which may be caused by such batteries.

Table of Contents