The stove must be installed with the following minimum clearances to side and back wall combustible materials. NOTE:
These are minimum clearances to combustible walls established by the testing lab. The amount of room needed on the left
side of the unit to access the electrical panel is (6) six inches (152mm).
PARALLEL - A - Left Sidewall to Top Edge of Unit
B - Sidewall to Flue
C - Backwall to Flue
D - Backwall to Unit
E - Right Sidewall to Top Edge of Unit
CORNER -
F - Adjacent Wall to Flue
G - Adjacent Wall to Unit
Backwall / Sidewall
Allow sufficient space to remove the left and right side panels for maintenance purposes.
These clearances must be maintained and may only be reduced by means approved by the regulatory authority
6
CLEARANCES TO COMBUSTIBLES
BACK WALL
Parallel
6"
HEARTH PROTECTION
min.
6 in./152mm
5 in./127mm
3 in./75mm
9 in./228mm
2 in./50mm
3 in./75mm
4 in./100mm
Corner Installation
NOTE:
BACK WALL
6"
min.
6"
min.