INSTALLATION CONFIGURATIONS
Note: Where passage through a wall, or partition of combustible construction is desired, the installation
shall conform to CAN/CSA -B365
The American Harvest Corn/Pellet Stove Model 6035 may be installed as follows:
1) A freestanding unit
2) A built-in heater mounted in an alcove
MOBILE HOME INSTALLATION REQUIREMENTS
IN ADDITION TO THE STANDARD INSTALLATION INSTRUCTION, THE FOLLOWING
REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME:
1) Stove must be permanently bolted to the floor.
2) Stove must have permanent outside air source. (60FAK)
3) Stove must be permanently electrically ground to the steel chassis of the mobile home.
4) All vertical chimney vent must have wall supports every (5) five feet.
5) All exhaust systems must have a spark arrestor.
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/
Check with your local building official as other codes may apply.
BOLT
USSC
WARNING
DO NOT INSTALL IN SLEEPING ROOM
CAUTION
ROOF MUST BE MAINTAINED.
PEDESTAL
FLOOR
STEEL CHASSIS
ELECTRICALLY
GROUNDED TO CHASSIS
9