Specifications; Contents - USSC Cavalier A9843L Installation And Operation Instructions Manual

Vent-free pedestal natural and propane gas heater
Table of Contents

Advertisement

Natural Gas
Manifold Pressure Setting 4" w.c.
Gas Inlet Pressure
Maximum 10-1/2" w.c.
Minimum 5" w.c.
Model Number
9843N
Propane / LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Manifold Pressure Setting 10" w.c.
Gas Inlet Pressure
Maximum 13" w.c.
Minimum 11" w.c.
Model Number
9843L
Controls - Main control has 4 positions:
1. OFF - All gas to the gas logs is shut off at the control
2. IGN - Piezo ignitor allows ignition of the pilot without the use of matches or batteries
3. PILOT - Valve position to light / maintain a standing pilot
4. ON - Gas flow to complete system, front burner ignition
Front Burner Control Knob - Infinite control, rotate clockwise to minimum rate and counter
clockwise for maximum rate.
Rear Burner Control Knob - Has 3 positions:
1. OFF - Gas to rear burner is shutoff at control
2. ON/MAX - Maximum gas flow to rear burner
3. MIN - Minimum gas flow rate to rear burner
9843L and 9843N Unvented Gas Heaters
1. Packet containing Homeowners/Installation instructions.
2. Log box containing four (4) fiber ceramic logs, refer to installation instructions.
3. Unvented gas heater.
CHECK THAT ALL LISTED PARTS HAVE BEEN RECEIVED
GLOVES ARE RECOMMENDED WHEN HANDLING CERAMIC FIBER LOGS
TO PREVENT SKIN IRRITATION FROM LOOSE FIBERS. LOGS ARE
FRAGILE, HANDLE WITH CARE.
Carefully inspect the contents for shipping damage and immediately inform your dealer if any damage is found.
Type
Max BTU/Hr
Manual
39,900
Type
Max BTU/Hr
Manual
39,900
5

SPECIFICATIONS

Gas Rate
Min BTU/Hr
10,000
Gas Rate
Min BTU/Hr
10,000
Number
of Burners
2
Number
of Burners
2

CONTENTS

Advertisement

Table of Contents
loading

Table of Contents