Clearances To Combustibles; Hearth Protection - USSC American Harvest 6037 Owner's Manual

Corn & pellet multifuel stove
Table of Contents

Advertisement

The stove must be installed with the following minimum clearances to side and back wall combustible materials. NOTE:
These are minimum clearances to combustible walls established by the testing lab. The amount of room needed on the left
side of the unit to access the electrical panel is (6) six inches (152mm).
PARALLEL - A - Left Sidewall to Top Edge of Unit
B - Sidewall to Flue
C - Backwall to Flue
D - Backwall to Unit
E - Right Sidewall to Top Edge of Unit
CORNER -
F - Adjacent Wall to Flue
G - Adjacent Wall to Unit
Allow sufficient space to remove the left and right side panels for maintenance purposes.
These clearances must be maintained and may only be reduced by means approved by the regulatory authority
USSC

CLEARANCES TO COMBUSTIBLES

BACK WALL
Backwall / Sidewall
Parallel

HEARTH PROTECTION

6"
min.
6 in./152mm
5 in./127mm
3 in./75mm
9 in./228mm
2 in./50mm
3 in./75mm
4 in./100mm
NOTE:
6"
min.
BACK WALL
Corner Installation
6"
min.
5