Step 5. Connecting Gas Line - Lennox Elite Series Installation Instructions Manual

B-vent multi-open
Table of Contents

Advertisement

B. Electronic Wiring
(also see figure 20 on page 11 )
Note: The electronic appliance must be con-
nected to the main power supply.
1. Route a 3-wire 120Vac 60Hz 1ph power
supply to the appliance junction box.
2. Open the control compartment access
panel, by actuating the spring-loaded
magnetic catches securing the panel,
gently depressing the outer top corners
of the panel until the catches "pop" the
panel free and allowing it to swing out
and down to open.
3. Remove the bottom control compartment
access panel by compressing the spring-
loaded hinge pin on the left side until it
disengages from the left cabinet panel
hole. Pull the panel away from the fire-
place. See Figure 22 on page 12.
4. Remove the modesty panel by pulling the
bottom right corner of the modesty panel
out slightly to disengage the snap-fit fea-
f i r e - p a r t s . c o m
ture; lift the modesty panel by the tab on
the panel's right end, pull the right end of
the panel away from the cabinet and then
pull the panel diagonally out of the left
side cabinet panel slots. (In the above
procedure, reverse the words "left" and
"right" for EBCR-2 models). Remove the
modesty panel carefully, so that none of
the wires become loose or disconnected.
5. Remove the outlet receptacle by removing
the two securing screws. See Figure 19.
(The left and right designations used here
are reversed in EBCR-2 applications.)
6. Install a field-provided strain relief in the
cabinet knockout opening for the protec-
tion of the power supply wires.
7. Connect the power supply wires to the
receptacle as shown in Figure 20 on
page 11.
8. Connect the ground supply wire and the
green wire attached to the outlet
receptacle's green ground screw.
9. Appliance-mounted ON/OFF burner con-
trol switch (rocker switch) is factory in-
stalled in the modesty panel. Optional
wall-mounted switch, thermostat, or one
of the optional remote control kits may
also be used.
FIREBOX BOTTOM
JUNCTION BOX
OUTLET RECEPTACLE
OUTLET RECEPTACLE
BOX SECURING SCREW
EBST-2, EBPF-2
AND EBCL-2 OUTLET RECEPTACLE SHOWN.
EBCR-2 HAS THE OUTLET RECEPTACLE LOCATED IN
THE LEFT CORNER OF THE UNIT
EBBAY OUTLET RECEPTACLE LOCATED IN
THE REAR LEFT CORNER OF THE UNIT
VIEW OF RIGHT BOTTOM CORNER OF UNIT
OUTLET RECEPTACLE INSTALLATION
Figure 19
10. If wall-mounted ON/OFF switch or thermo-
stat is to be used, mount it in a convenient
location on a wall near the fireplace.
11. If the wall-mounted ON/OFF switch is to be
used, wire it to the the low voltage circuit
as shown in Figure 20 on page 11.
Note: The supplied 15 feet of 2 conductor wire
has one end of each conductor connected to
the gas valve circuit and the other end of each
conductor placed loose inside the lower com-
partment of the unit.
12. After wiring is complete, reinstall the out-
let receptacle; install the field-provided
the metal junction box cover plate; rein-
stall the modesty panel.
Note: The gas valve ON/OFF switch is shown in
Figure 20 on page 11. It is integral with the gas
valve and should be set to the ON position.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
IMPORTANT: Ground supply wire must be
connected to the green wire attached to
CABINET
the outlet receptacle's green ground screw.
RIGHT SIDE
See Figure 20 on page 11 . Failure to do so
PANEL
will result in a potential safety hazard. The
appliance must be electrically grounded
in accordance with local codes or, in the
absence of local codes, the National Elec-
trical Code, ANSI/NFPA 70-(latest edition).
(In Canada, the current CSA C22-1 Cana-
dian Electrical Code.)

Step 5. CONNECTING GAS LINE

Make gas line connections. All codes require a
shut-off valve mounted in the supply line.
Figure 21 on page 12 illustrates two methods
for connecting the gas supply. The flex-line
method is acceptable in the U.S., however,
Canadian requirements vary depending on lo-
cality. Installation must be in compliance with
local codes.
Electronic Wiring Diagram (Honeywell)
1. If any of the original wire as supplied must be replaced,
1.
it must be replaced with Type AWM 105°C – 18 GA.
wire.
2. 120V, 60Hz – Less than 3 amps.
*ON/OFF Switch (Integral
with Gas Valve)
Gas Valve
BK
R
BL
WT
LIMIT SWITCH
APPLIANCE-MOUNTED ON/OFF SWITCH
**Turn the appliance-mounted ON/OFF burner control switch to
the OFF position if an optional control switch is installed.
Factory Wired
Schematic Representation Only
Figure 20
*Leave the ON/OFF switch, which is integral
with the gas valve, in the ON position.
Outlet Box Green
Ground Screw
PILOT
G
ASSEMBLY
120
BK
VAC.
W
G
White Wire
To Opposite
Side
Junction Box
W
Transf.
B
120 V.
G
Hot side of Outlet
24 V
BL
R
BK
WT
**OPTIONAL WALL SWITCH
OR OPTIONAL THERMOSTAT
OR OPTIONAL REMOTE
RECEIVER
Field Wired
11