3.1 SECURITY SYSTEM

The voltage of single-phase motors connected with their switch is 230V and 400V for three-phase.
• The international standards for the drill equipment with diamond recommend to have the energy unit
should be connected to the power through a specific security system, equipped with an adequate residual
interrupter.
• The security system is supposed to have:
- Portable differentials box, with one or more plugs, with a stream cutting residual and a special plug for
drill units with diamond.
- The differential switch, incorporated in the cable, in those countries where the law permits it only for
single-phase motors.
- WARNING: It is not sufficient to have the differential interrupter integrated in the feeding.
Before starting to work, check the security system switch. To do so, proceed as follows:
- Plug the differentials box or differential switch (position 1) ON.
- Press the check-up button (T), the switch should jump to OFF position.
NOTE: If during the work, the stream circuit is burnt, disconnect the machine and stop drilling. Check
the fault and solve it.

3.2 SPECIAL PLUGS

The unit is equipped with a normalised, special plug (ECC) that needs to be connected to a secured
switchboard that has a normalised connection base.
Never remove the plug from the cable nor mount another plug.

3.3 EXTENSION CABLES

-
If you need to use an extension cable, always use cables with earth plug.
-
The plug and the peg of the extension cable should be mounted with an electrical cable with a H07RN-F
rubber outer cover.
-
The extension cable needs to have the adequate length and the corresponding section to the drill power
to avoid high energy consumption.
-
(110/230V) Voltage: if you use an extension between the electrical source and the transformer, the
extension needs to have a 9A.
-
If you use an extension between a transformer and an electrical tool, the extension needs to have a 16A
tension.
-
When using more than one cable to get the desired length, make sure each individual extension has the
minimal Amperes value (A) en function of the length of the cables.
AMPERS (A)
QUICK GUIDE TO CABLE SELECTION
EXTENSION CABLES MINIMAL SIZE
7,5
5,1 - 7
2,5
7,1 - 10
2,5
10,1 - 16
4
16,1 - 22
4
- 4 -
CABLE LENGTH IN (m)
15
25
30
45
2,5
2,5
2,5
2,5
2,5
2,5
2,5
2,5
4
4
6
4
6
6
60
2,5
4
6
6
6
-
ENGLISH