Trane 4TXCA002DS3HCA Installer's Manual

Trane 4TXCA002DS3HCA Installer's Manual

Cased aluminum "convertible" coils

Advertisement

Installer's Guide
Cased Aluminum "Convertible" Coils
Models:
4TXCA002DS3HCA
4TXCA032DS3HCA
4TXCB003DS3HCA
4TXCB004DS3HCA
4TXCB006DS3HCA
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT - This Document is customer property and is to remain with this unit. Please return to service informa-
tion pack upon completion of work.
WARNING
!
WARNING (Medium/high pressure)
Contains Refrigerant!
System contains oil and refrigerant under high pressure.
Recover refrigerant to relieve pressure before opening the
system. See unit nameplate for refrigerant type. Do not
use non-approved refrigerants, refrigerant substitutes, or
refrigerant additives.
Failure to follow proper procedures or the use of non-
approved refrigerants, substitutes, or refrigerant additives
could result in death, serious injury, or equipment damage.
!
This product can expose you to chemicals including lead, which
are known to the State of California to case cancer and birth defects
or other reproductive harm. For more information go to www.
P65Warnings.ca.gov
A. GENERAL
These coils are designed for use in combination with a heat pump
or cooling outdoor section using R-410A REFRIGERANT.
The 4TXC equipment has been evaluated in accordance with
the Code of Federal Regulations, Chapter XX, Part 3280 or the
equivalent. "Suitable for Mobile Home use" The height of the
Furnace, Coil and discharge duct work must be 7 ft. or less.
Inspect the coil for shipping damage. Notify the transporta-
tion company immediately if the coil is damaged.
B. APPLICATION INFORMATION
1. FURNACE AND COIL
The coil MUST BE installed downstream (in the outlet air)
of the furnace.
2. INDOOR UNIT AIRFLOW
Indoor unit must provide the required airflow for the heat
pump or cooling combinations approved for these coils.
4TXCC005DS3HCA
4TXCC007DS3HCA
4TXCD008DS3HCA
4TXCC009DS3HCA
4TXCD010DS3HCA
WARNING
18-AD35D1-2D-EN

Table of Contents

General ............................................................................... 1
Application Information ................................................ 1
Recommendation ............................................................. 2
Furnace in Upflow Position .......................................... 2
Furnace in Downflow Position ..................................... 2
Furnace in Horizontal Right Position ........................ 3
Furnace in Horizontal Left Position ........................... 4
Maximum Airflow Setting, CFM ................................... 5
Installing / Brazing Refrigerant Lines ....................... 5
Leak Check........................................................................ 6
Condensate Drain Piping .............................................. 6
Cleaning the Coil ............................................................. 6
Outline Drawings ............................................................ 7
NOTE:
OPTIONAL DOWNFLOW GASKET INSTALLATION: For
unusually humid applications that expect prolonged
operation above 70% RH, it is recommended to use the
BAYGSKT001A0 gasket kit to prevent water from forming
on the bottom of the drain pan and dripping into the sup-
ply ductwork.
IMPORTANT: Review your installation requirements. Check
the table on the outline drawings and note all dimensions
for your coil before beginning the installation.
Figure 1
A341869P33

Advertisement

Table of Contents
loading

Summary of Contents for Trane 4TXCA002DS3HCA

  • Page 1: Table Of Contents

    18-AD35D1-2D-EN Installer’s Guide Cased Aluminum "Convertible" Coils Models: 4TXCC005DS3HCA 4TXCA002DS3HCA 4TXCC007DS3HCA 4TXCA032DS3HCA 4TXCD008DS3HCA 4TXCB003DS3HCA 4TXCC009DS3HCA 4TXCB004DS3HCA 4TXCD010DS3HCA 4TXCB006DS3HCA ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service informa- tion pack upon completion of work.
  • Page 2: Recommendation

    The gasket material can be cut or ripped easily so that it can be tailored to fit. The gasket material must Figure 4 cover the three sides along the entire length of the coil as shown in Figure 4. 18-AD35D1-2D-EN © Trane 2018...
  • Page 3: Furnace In Horizontal Right Position

    Installer’s Guide F. FURNACE IN HORIZONTAL RIGHT POSITION CAUTION Both the coil and furnace must be fully supported. Do not attempt to suspend the coil using the brackets. Note: when installing onto an S-Series furnaces in horizontal right or downflow configuration the flanges will be bent downward.
  • Page 4: Furnace In Horizontal Left Position

    Installer’s Guide G. FURNACE IN HORIZONTAL LEFT POSITION Figure 8 CAUTION Both the coil and furnace must be fully supported. Do not attempt to suspend the coil using the brackets. 1. HORIZONTAL LEFT COIL CONVERSION: While not required, optional removal of some coil components will maximize airflow efficiency.
  • Page 5: Maximum Airflow Setting, Cfm

    Maximum airflow setting, CFM Coil Upflow Horizontal Left 1. The following steps are to be considered when installing 4TXCA002DS3HCA the refrigerant lines: 4TXCA032DS3HCA 1350 1125 a. Determine the most practical way to run the lines.
  • Page 6: Leak Check

    Installer’s Guide L. CLEANING THE COIL Capillary tubes will The two piece door (3-piece on 24.5" wide models) allows come out the top of removal of the outer casing doors without interference from bulb when positioned refrigerant or condensate lines. Once the outer doors are correctly.
  • Page 7: Outline Drawings

    Installer’s Guide 18-AD35D1-2D-EN...
  • Page 8 Installer’s Guide 18-AD35D1-2D-EN...
  • Page 9 Installer’s Guide 18-AD35D1-2D-EN...
  • Page 10: Troubleshooting Indoor Txv / Cooling Mode

    Installer’s Guide Before starting, insure the blower wheel, indoor and outdoor Troubleshooting Indoor TXV / Cooling Mode coils are clean. Correct air Is sub cooling at the Is superheat Is air flow at least flow outdoor unit between < 5F? 350 CFM per ton? problem 8 to 12F?
  • Page 11 Installer’s Guide 18-AD35D1-2D-EN...
  • Page 12 Trane 12/18 6200 Troup Highway Tyler, TX 75707 Since the manufacturer has a policy of continuous product and product data improvement, it reserves the For more information contact right to change design and specifications without notice. your local dealer (distributor)

Table of Contents