QUORUM INTERNATIONAL Mykonos 72" Installation Instructions Manual

Advertisement

Quick Links

THE MYKONOS 72" & 92" CEILING FAN
INSTALLATION INSTRUCTIONS
Please read and save these instructions
These instructions are to be used in
the installation of the following
QUORUM INTERNATIONAL fans...
The Mykonos 72" & 92"
© 2018 Quorum International. All Rights Reserved.
P.O. Box 961008 • Fort Worth, TX 76161 • (817) 626-5483 • FAX (817) 626-5540
I0267-11/18

Advertisement

Table of Contents
loading

Summary of Contents for QUORUM INTERNATIONAL Mykonos 72"

  • Page 1 These instructions are to be used in the installation of the following QUORUM INTERNATIONAL fans... The Mykonos 72" & 92" © 2018 Quorum International. All Rights Reserved. P.O. Box 961008 • Fort Worth, TX 76161 • (817) 626-5483 • FAX (817) 626-5540 I0267-11/18...
  • Page 2: Warranty & Service

    QUORUM'S UNIQUE LIMITED LIFETIME WARRANTY This warranty gives you specific legal technical skill, competence, or experience superior product if the defective unit is of the user. rights, and you may also have other rights returned prepaid to us. which vary from state to state. 8.
  • Page 3: Safety Rules

    1. SAFETY RULES Models #67210-xx: 48.28 lbs 69210-xx: 56.88 lbs 1. To avoid possible electric shock, turn 6. WARNING- Support Directly from TOOLS REQUIRED the Building Structure. off the electricity at the main fuse box or FOR INSTALLAITON circuit panel before you begin the fan 7.
  • Page 4: Unpacking Your Fan

    2. UNPACKING YOUR FAN Unpack your fan and check the contents. Do not discard the carton. If warranty replacement or NOTE: repair is ever necessary the fan should be returned in original packaging. Remove all parts and Some Quorum fan models will have slightly hardware.
  • Page 5: Mounting Options

    3. MOUNTING OPTIONS 1. Disconnect the power by removing fuses or turning off circuit breakers. Fig. 1 Ceiling Joists 2. The support structure must be securely mounted and capable of reliably supporting a minimum of 70 pounds (31.8 kg). WARNING: Support Directly from the Building Structure. 3.
  • Page 6: Hanging Your Fan

    4. HANGING YOUR FAN WARNING -Turn off the power! Fig. 4 Fig. 6 1. Remove the motor top housing and Screws metal washer by remove the six screws with lock washers from the motor collar. Hanger Metal washer bracket (Fig. 4) 2.
  • Page 7 4. HANGING YOUR FAN (continued) WARNING -Turn off the power! Fig. 9 Fig. 11 1. (Fig. 9) Remove the set pin and safety lock clip from the yoke on top of the motor assembly. Slide the downrod through the canopy and canopy cover. Downrod Slide the yoke cover onto the downrod.
  • Page 8: Electrical Connections

    5. ELECTRICAL CONNECTIONS REMEMBER -Turn off the power! NOTE - Control must be installed within 30 feet of fan. Use the wire nuts supplied with your fan If your junction box has a ground Use ONLY wall controls approved by when making connections.
  • Page 9 6. COMPLETING INSTALLATION 1. Make sure the wiring is safely inside the Fig. 13 Fig. 16 outlet box as instructed in Step 5 - Electrical Connections. To install the Outlet box canopy, slide the canopy up to hanger bracket and place the key hole on the Hanger canopy over the screw on the hanger bracket...
  • Page 10 7. INSTALLING THE WALL CONTROL REMEMBER -Turn off the power! NOTE - Control must be installed within 30 feet of fan. Fig. 19 1. Remove the existing wall plate and 3. (Fig. 19) Carefully tuck the wire switch from the wall junction box. connections inside the junction box.
  • Page 11 OPERATING TRANSMITTER YOUR (continued) If a room has two fans installed, each fan NOTE: If multiple fans are installed on The receiver provides the following the same circuit, each fan must have it’s protective function: will need it’s own wall control. A single own switch leg.
  • Page 12: Troubleshooting

    10. TROUBLESHOOTING 3. Use of a standard light rheostat or an FAN WILL NOT START EXCESSIVE WOBBLE 1. Check that the electricity has been unapproved fan wall control to control the Note: A small amount of wobble is turned on at the circuit breaker which had fan speed will always cause an annoying considered acceptable and should not be probably been turned off during...

This manual is also suitable for:

Mykonos 92"

Table of Contents