Download Print this page
YASKAWA DeviceNet Instruction Sheet
YASKAWA DeviceNet Instruction Sheet

YASKAWA DeviceNet Instruction Sheet

Satellite board for gpd 333 adjustable frequency drives

Advertisement

Quick Links

This option may have been installed by the factory. However, certain steps can
only be completed at the installation site. Therefore, review and then perform
those steps which will complete the installation process.
Before installing this option, a TECHNICALLY QUALIFIED INDIVIDUAL who is
familiar with this type of equipment and the hazards involved, should READ THIS
ENTIRE INSTRUCTION SHEET.
The DeviceNet Satellite board is an electrostatic sensitive device. Personnel must
use approved methods for handling this type of equipment.
HAZARDOUS VOLTAGE CAN CAUSE SEVERE INJURY OR
DEATH. ENSURE ALL POWER SOURCES FEEDING DRIVE
ARE LOCKED IN THE "OFF" POSITION BEFORE INSTALLING
THIS OPTION.
INTRODUCTION
The DeviceNet network is a low-cost communications network used to connect industrial devices (such as limit
switches, photoelectric switches, valve manifolds, motor starters, smart motor controllers, operator interfaces,
and variable frequency drives) as well as control devices (such as programmable controllers and computers).
The DeviceNet network can accommodate up to 64 nodes per network. A GPD 333 appears as one node on the
network. A DeviceNet Satellite board (MagneTek part no. CM051) must be installed into each GPD 333 drive that
will be communicating on the DeviceNet network. The GPD 333 DeviceNet Satellite resides on the front of the
drive in the location normally used by the status plate or the Digital Operator. The Satellite board is powered from
both the 24VDC DeviceNet network power and the GPD 333 drive that it is connected to.
CHANGE RECORD
DEVICENET SATELLITE
MODEL CM051
NOTE
CAUTION
CAUTION
WARNING
For GPD 333
Adjustable Frequency Drives
DWG. NO. 02Y00025-0387
SHEET NO. 1 OF 4
REL. 5/7/96
( m - df )

Advertisement

loading

Summary of Contents for YASKAWA DeviceNet

  • Page 1 (such as programmable controllers and computers). The DeviceNet network can accommodate up to 64 nodes per network. A GPD 333 appears as one node on the network. A DeviceNet Satellite board (MagneTek part no. CM051) must be installed into each GPD 333 drive that will be communicating on the DeviceNet network.
  • Page 2 40 mA SYSTEM CONNECTIVITY The table below shows the Connector Pinout for the GPD 333 DeviceNet Satellite. For information on DeviceNet network topology, maximum cable distance, cable specifications, and network termination, refer to the GPD 333 DeviceNet Satellite technical manual, TM 4336.
  • Page 3 ? I 4 @ @ @ @ @ @ @ @ @ ) K ? I ' @ @ @ @ @ @ @ @ @ 6 K The DeviceNet Satellite installs directly on the GPD W 2 @ @ @ @ @ @ @ @ @ @ ( M...
  • Page 4 DIPSWITCH SETTINGS Baud Rate Switch 1 Switch 2 SWITCH # SWITCH FUNCTION 125 Kbaud 250 Kbaud Baud Rate, Bit 1 500 Kbaud Baud Rate, BIt 0 500 Kbaud GPD 333 Node Address, MSB GPD 333 Node Address Network Control of Frequency Switch 9 GPD 333 Node Address GPD 333 Node Address...

This manual is also suitable for:

Cm051