Bosch DSA E Series Installation Manual page 14

Iscsi disk arrays
Hide thumbs Also See for DSA E Series:
Table of Contents

Advertisement

14
en | Preparing for an E2600 Controller-Drive Tray Installation
Table 2.3 Cables and Connectors
- | V2 | 2012.09
Item
AC power cords.
The controller-drive tray and the drive trays
ship with power cords for connecting to an
external power source, such as a wall plug.
Your cabinet might have special power
cords that you use instead of the power
cords that ship with the controller-drive
tray and the drive trays.
(Optional) Two DC power connector cables
are provided with each drive tray for
connection to centralized DC power plant
equipment.
Four DC power connector cables are
provided if additional redundancy is
required.
A qualified service person is required
to make the DC power connection per
NEC and CEC guidelines. A two-pole
20-amp circuit breaker is required
between the DC power source and the
drive tray for over-current and short-
circuit protection. Before turning off
any power switches on a DC-powered
drive tray, first you must disconnect
the two-pole 20-amp circuit breaker.
Copper SAS cables - Use for all drive-side
connections within the storage array.
Fiber-optic cables - Use for FC connections
to the drive trays.
For the differences between the fiber-optic
cables and the copper Fibre Channel (FC)
cables, see Section 2.2.3 Things to Know –
SFP Transceivers, Fiber-Optic Cables, Copper
Cables, and SAS Cables, page 17
Installation Manual
E2600 DSA E-Series iSCSI Disk Arrays
Included with the
Controller-Drive
Tray or Drive Trays
Yes
Yes
For the DC power
option only