National Instruments PXI-1000B Installation Manual

National Instruments PXI-1000B Installation Manual

Ac power supply shuttle
Hide thumbs Also See for PXI-1000B:

Advertisement

Quick Links

INSTALLATION GUIDE
PXI
-1000B AC P
Contents
National Instruments
, ni.com
trademarks or trade names of their respective companies.
323069A-01
OWER
Important Information............................................................................. 2
For Your Safety....................................................................................... 3
Getting Started ........................................................................................ 4
Unpacking ........................................................................................ 4
What You Need to Get Started ........................................................ 4
Key Features .................................................................................... 4
Removal, Configuration, and Installation ............................................... 6
Removal ........................................................................................... 6
Configuration ................................................................................... 6
Installation ....................................................................................... 6
Connecting Safety Ground............................................................... 7
Maintenance ............................................................................................ 9
Service Interval ................................................................................ 9
Preparation ....................................................................................... 9
Cleaning ........................................................................................... 9
Exterior Cleaning...................................................................... 10
Cleaning the Fan Filters............................................................ 10
, and PXI
are trademarks of National Instruments Corporation. Product and company names mentioned herein are
Copyright © 2001 National Instruments Corp. All rights reserved.
S
S
UPPLY
HUTTLE
April 2001

Advertisement

Table of Contents
loading

Summary of Contents for National Instruments PXI-1000B

  • Page 1: Table Of Contents

    ™ National Instruments , ni.com , and PXI are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. 323069A-01 Copyright © 2001 National Instruments Corp. All rights reserved. April 2001...
  • Page 2: Important Information

    Warranty The PXI-1000B AC power supply shuttle is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period.
  • Page 3: For Your Safety

    Chassis Grounding—The PXI-1000B AC power supply shuttle requires a connection from the premise wire safety ground to the PXI-1000B AC chassis ground. The earth safety ground must be connected during use of this equipment to minimize shock hazards. Refer to the...
  • Page 4: Getting Started

    Getting Started This section describes the key features of the PXI-1000B AC power supply shuttle and lists the contents of your kit. Unpacking Carefully inspect the shipping container and the power supply shuttle for damage. Check for visible damage to the metal work. Check to make sure all handles, hardware, and switches are undamaged.
  • Page 5 Figure 1 shows an isometric view of the PXI-1000B AC power supply shuttle. Figure 2 shows a rear view. Figure 1. Isometric View of the PXI-1000B AC Power Supply Shuttle 1 Module Cooling Air Outlets 3 Remote Power Status and Inhibit Connector...
  • Page 6: Removal, Configuration, And Installation

    Removal The PXI-1000B AC power supply shuttle is a replacement part for the PXI-1000B AC chassis. Before attempting to replace the power supply shuttle, verify that there is adequate clearance behind the chassis. Set the power switch on the front panel to the Standby position and disconnect the power cord from the power supply shuttle on the back of the chassis.
  • Page 7: Connecting Safety Ground

    Connecting to Power Source and Testing Power Up Caution Remove all PXI modules from the PXI-1000B chassis prior to performing the first power on test. Attach the appropriate power cord to the rear AC inlet and an electrical power outlet.
  • Page 8: Remote Power Monitoring And Inhibiting Interface

    Remote Power Monitoring and Inhibiting Interface The PXI-1000B AC power supply shuttle supports remote power monitoring and inhibiting via a 9-pin D-sub connector on the rear panel. Table 3 shows the pinout of the DB-9 connector.
  • Page 9: Maintenance

    CompactPCI or PXI modules. Always power-off the chassis and disconnect the power cord before cleaning or Caution servicing the power supply shuttle. © National Instruments Corporation PXI-1000B AC Power Supply Shuttle Installation Guide...
  • Page 10: Exterior Cleaning

    Clean the fan filters by washing them in a mild soap solution and then drying them by vacuuming or blowing air through them. Rinse the filters with water and allow them to dry before reinstalling them on the power supply shuttle. PXI-1000B AC Power Supply Shuttle Installation Guide ni.com...