Troubleshooting Guide; Installation - Cerwin-Vega Vega Series User Manual

Digital bass enhancer
Hide thumbs Also See for Vega Series:
Table of Contents

Advertisement

Guide
TROUBLE SHOOTING GUIDE
If the Unit does not turn-on, and/or the power indicator LED is NOT illuminated, do this:
1) Check and make sure that B+ and GND are not reversed.
2) Check that all power wires are properly connected and have the appropriate potential (11-16 volts)
3) Check that the fuse is intact and funtioning.
If you experience high audible distortion or low output volume:
4) Check that the input and output levels are set correctly. Input should match the source and output should match
the sensitivity of the host.
5) Check the crossover settings; make sure they are correct; for a high "Q" systems, set it 1 octave or more
above.
If you experience high audible distortion or low output volume:
6) Verify that the GND connection is secure, the conductor (wire) is not too thin and unnecessarily long.
7) Check that the B+wire is not too thin and unnecessarily long.
8) Change the power source; try taking power from a different point.

INSTALLATION

TAPPING SCREW
SPRING WASHER
PLAIN WASHER
9