Download Print this page

Graco Dura-Flo 900 Series Instructions-Parts List Manual page 6

Stainless steel pumps

Advertisement

General Information
NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
NOTE: Always use Genuine Graco Parts and Acces-
sories, available from your Graco distributor. Refer to
Product Data Sheet, Form No. 305715 (Senator
Pumps), Form No. 305716 (Bulldog Pumps), and Form
No. 305717 (King Pumps). If you supply your own
accessories, be sure they are adequately sized and
pressure rated for your system.
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE OR EXPLOSION HAZ-
ARD on page 5.
1. King Pumps: use a ground wire and clamp. See
Fig. 1. Remove the ground screw (Z) and insert
through eye of ring terminal at the end of ground
wire (Y). Fasten ground screw back onto pump
and tighten securely. Connect the other end of
ground wire to a true earth ground. Order Part No.
222011 Ground Wire and Clamp.
All Other Pumps: use a ground wire and clamp.
See Fig. 2. Loosen the grounding lug locknut (W)
and washer (X). Insert one end of a 1.5 mm@ (12
ga) minimum ground wire (Y) into the slot in lug (Z)
and tighten the locknut securely. Connect the other
end of the wire to a true earth ground. Order Part
No. 237569 Ground Wire and Clamp.
Z
Fig. 1
6
308354
Installation
Fig. 2
2. Air and fluid hoses: use only electrically conductive
3. Air compressor: follow manufacturer's recommen-
4. Spray gun: ground through connection to a prop-
5. Fluid supply container: follow your local code.
6. Object being sprayed: follow your local code.
7. Solvent pails used when flushing: follow your local
8. To maintain grounding continuity when flushing or
System Accessories
Fig. 3 is only a guide for selecting and installing sys-
tem components and accessories. Contact your Graco
distributor for assistance in designing a system to suit
your particular needs.
Air and Fluid Hoses
Be sure all air hoses (H) and fluid hoses (N and P) are
properly sized and pressure-rated for your system.
Use only electrically conductive hoses. Fluid hoses
must have spring guards on both ends. Use a whip
hose (P) and a swivel (R) between the main fluid hose
(N) and the gun (S) to allow freer gun movement.
Y
Mounting Accessories
Mount the pump (A) to suit the type of installation
planned. Fig. 3 illustrates a wall mount system. Pump
dimensions and the mounting hole layout are shown
on page 33.
TI1052
If you are using a floor stand, refer to its separate
manual for installation and operation instructions.
W
Y
hoses.
dations.
erly grounded fluid hose and pump.
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.
relieving pressure, hold a metal part of the spray
gun firmly to the side of a grounded metal pail,
then trigger the gun.
X
Z
0864

Advertisement