Sun Microsystems Ultra 2 UltraSPARC-II Upgrade
Sun Microsystems Ultra 2 UltraSPARC-II Upgrade

Sun Microsystems Ultra 2 UltraSPARC-II Upgrade

Hide thumbs Also See for Ultra 2 UltraSPARC-II:

Advertisement

Quick Links

Sun Microsystems Ultra 2 UltraSPARC-II Upgrade

Advertisement

Table of Contents
loading

Summary of Contents for Sun Microsystems Ultra 2 UltraSPARC-II

  • Page 1 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
  • Page 2 ™ ™ Ultra ™ UltraSPARC -II Module Upgrade Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Part No.: 805-0936-14 October 1999, Revision A Send comments about this document to: docfeedback@sun.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 Sun, Sun Microsystems, the Sun logo, AnswerBook, SunDocs, Ultra, OpenBoot, UltraSPARC, and Solaris are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and in other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the United States and in other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc.
  • Page 4: Table Of Contents

    Contents Electromagnetic Compatibility v UltraSPARC-II Module Upgrade 1-1 System Software Requirements 1-2 1.1.1 Minimum Solaris Operating Environment 1-2 1.1.2 OpenBoot PROM 1-2 System Hardware Requirements 1-2 SCD Compliance UltraSPARC-II Module Upgrade Kit 1-3 Opening the System Unit 2-1 Removing Power from the System 2-1 Removing the System Unit Cover 2-3 Attaching the Wrist Strap 2-5 Installing the UltraSPARC-II Module 3-1...
  • Page 5 Turning On the Power 3-11 3.4.4 Power-On Self-Test (POST) 3-11 3.4.5 EnergyStar 3-11 3.4.6 Returning the Removed Module(s) 3-12 Sun Ultra 2 UltraSPARC-II Module Upgrade • October 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 6: Electromagnetic Compatibility

    Electromagnetic Compatibility FCC Class B Notice — United States This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause operation.
  • Page 7 B prescrites dans le Règlement sur le brouillage radioélectriques édicté par le Ministère des Communications du Canada. Sun Ultra 2 UltraSPARC-II Module Upgrade • October 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 8 Nippon — Japan -vii Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 9 -viii Sun Ultra 2 UltraSPARC-II Module Upgrade • October 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 10: Ultrasparc-Ii Module Upgrade

    C H A P T E R UltraSPARC-II Module Upgrade This book contains procedures for installing an UltraSPARC™-II module upgrade in a Sun™ Ultra™ 2 system. The Sun Ultra 2 system can now support a 400-Mhz CPU if the motherboard is part number 501-3132-13 or higher. Ultra 2 System FIGURE 1-1 Artisan Technology Group - Quality Instrumentation ...
  • Page 11: System Software Requirements

    The system responds with the quantity (for example, 2 x) and speed (168 MHz) of the UltraSPARC module(s) installed. Sun Ultra 2 UltraSPARC-II Module Upgrade • October 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 12: Scd Compliance

    SCD Compliance Sun Ultra 2 systems have been independently tested and verified to comply with revision 2.1 of the SPARC Compliance Definition (SCD) developed by SPARC International, Inc. These systems are binary compatible with all other systems and software that conform to SCD version 2.1. SCD Compliance FIGURE 1-2 UltraSPARC-II Module Upgrade Kit...
  • Page 13 Sun Ultra 2 UltraSPARC-II Module Upgrade • October 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 14: Opening The System Unit

    C H A P T E R Opening the System Unit This chapter contains the following sections: Section 2.1, “Removing Power from the System,” on page 2-1 Section 2.2, “Removing the System Unit Cover,” on page 2-3 Section 2.3, “Attaching the Wrist Strap,” on page 2-5 Removing Power from the System Before turning off system power, shut down the operating system to avoid loss of data.
  • Page 15 AC voltage is still present in the power supply primary. Standby Standby Switch FIGURE 2-1 Sun Ultra 2 UltraSPARC-II Module Upgrade • October 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 16: Removing The System Unit Cover

    Front Panel LED Location FIGURE 2-2 Removing the System Unit Cover 1. Use a Phillips screwdriver to remove the lock block (if installed) on the top cover and back panel ( FIGURE 2-3 2. Pull the two top cover plastic tabs towards yourself. 3.
  • Page 17 Lock block Plastic tab Plastic tab Opening the System Unit FIGURE 2-3 Lifting the Top Cover FIGURE 2-4 Sun Ultra 2 UltraSPARC-II Module Upgrade • October 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 18: Attaching The Wrist Strap

    Attaching the Wrist Strap Attach end to metal casing of power supply Wrap the wrist strap twice around your wrist (adhesive against your skin). Attaching the Wrist Strap FIGURE 2-5 Power supply Power Supply Location FIGURE 2-6 Chapter 2 Opening the System Unit Artisan Technology Group - Quality Instrumentation ...
  • Page 19 Sun Ultra 2 UltraSPARC-II Module Upgrade • October 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 20: Installing The Ultrasparc-Ii Module

    C H A P T E R Installing the UltraSPARC-II Module Updating the Flash PROM Use Sun™ Flash PROM Guide for Workstations and Workgroup Servers - Standalone Version, part number 802-3233, for updating your system’s flash PROM. Removing the UltraSPARC Module The Sun Ultra 2 system can now support a 400-Mhz CPU if the motherboard is part number 501-3132-13 or higher.
  • Page 21 3. Lift the module upwards until it clears the system chassis. 4. Place the module on an antistatic surface. Sun Ultra 2 UltraSPARC-II Module Upgrade • October 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 22: Installing The Ultrasparc-Ii Module

    90-degrees 90-degrees 135-degrees 135-degrees Removing the UltraSPARC Module FIGURE 3-2 Installing the UltraSPARC-II Module Caution – All CPUs must have the same clock speed. 1. Unpack the UltraSPARC-II processor module. 2. Place the module on an antistatic surface. 3. Identify the appropriate or available slot ( FIGURE 3-3 Chapter 3 Installing the UltraSPARC-II Module...
  • Page 23 If your system is equipped with two UltraSPARC-II modules, slot 0 and slot 1 will each have a module installed. Sun Ultra 2 UltraSPARC-II Module Upgrade • October 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 24 4. On the antistatic surface, hold the module in an upright position so that the plastic surface faces you ( FIGURE 3-4 5. Move the levers on the module to the 135-degree position. 6. Lower the module along the vertical plastic guides until the module touches the slot socket on the main logic board.
  • Page 25 Steps 5 through 7 of this procedure to install the UPA terminator (501-4843-01) in slot 1 if necessary. Refer to on page 4. TABLE 3-1 Sun Ultra 2 UltraSPARC-II Module Upgrade • October 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 26: Completing The Installation

    Completing the Installation 3.4.1 Changing the Clocking Select Jumper The following table gives information about the clocking select jumper functionality. The following figures show the location of the clocking select jumper on the main logic board, and the two available jumper settings, respectively. To change the jumper;...
  • Page 27 CPU — 1 J2901 Part number label Speaker Front Panel Clocking Select Jumper Location on Ultra 2 Motherboard FIGURE 3-6 Sun Ultra 2 UltraSPARC-II Module Upgrade • October 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 28 Pin 1 Pin 2 Pin 3 J2301 Default jumper position, UltraSPARC-I modules, 168 MHz and 200 MHz; UltraSPARC-II 400 MHz J2301 Jumper position, UltraSPARC-II modules, 250 MHz and 300 MHz J2301 Clocking Select Jumper Positions FIGURE 3-7 3.4.2 Closing the System Unit 1.
  • Page 29 5. Use a Phillips screwdriver to reinstall the lock block to the back panel. Plastic tab Lock block Plastic tab Cover Tabs and Lock Block FIGURE 3-9 3-10 Sun Ultra 2 UltraSPARC-II Module Upgrade • October 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 30 3.4.3 Turning On the Power 1. Reattach all cords and cables connected to the system unit. 2. Turn on the power in this order: External SCSI peripheral with SCSI terminator attached External SCSI peripheral daisy-chained to the SCSI peripheral with the SCSI terminator attached Monitor Power On/Standby switch on the system unit back panel.
  • Page 31 3.4.6 Returning the Removed Module(s) To return the removed module(s) to Sun Microsystems, Inc., use the shipping box and packing materials for the UltraSPARC module(s) and: 1. Place the removed module(s) in the antistatic bag(s). 2. Fold and tape the end(s) of the bag(s).
  • Page 32 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...

Table of Contents