Installation

WARNING! Do not connect the appliance to the mains until the installation is fully complete.
Important, in circulating-air mode, first rotate the conversion valve to filtering position (posi-
tion F) and then fix the air outlet hole cap, otherwise the conversion valve might jam.
To a wall-hanging cupboard
With 4 screws.
1. Dimensions for the mounting boreholes
can be found in, or place a template on
the base of the wallhanging cupboard.
Selecting the operating mode:
A
F
■ Exhaust-air mode: Position A
A
F
■ Circulating-air mode: Position F
24
2. Mark the mounting holes and make pilot
holes with a bradawl.
In exhaust-air mode (upwards) mark the
exhaust-air opening and saw out.
In circulating-air
mode, apply the
plug supplied to
close the exhaust
hole.
■ Consider the location of the connection
cable; if required, saw out the cupboard.
3. Remove the filter grille (see Instructions
for use).
4. Screw the extractor hood to the base of
the cupboard.