9. Remove the power cord from the refrigeration
assembly.
a. Slide the bushing sideways away from the
refrigeration module until it is free (Figure 7).
Avoid bending the refrigeration tubing.
b. Pull the power cord through the module.
Bushing
Figure 7: Remove line cord from module

Module Replacement

Complete the following to install the new refrigerator
module.
10. Ensure that the control wiring runs through the
channel in the refrigerator body (Figure 8).
Note
Two thick, black cables connect the power supply with
the AC and compressor (Figure 8). Ensure that
cables are side by side and not crossed during
reassembly.
Power supply
cables
Figure 8: Rear view with module removed
11. Install the evaporator temperature sensor at the
top of the sixth coil (Figure 6), using the cable
ties provided.
To operate correctly, the sensor must be
mounted in the exact position illustrated in
Figure 6.
Instruction Sheet 60-4702-048 Revision H, November 8, 2019
Note
When installing the black
molded sensor do not
overtighten the cable tie on the
sensor body, as internal
damage may occur. The sensor
should be snug against the coil,
but the rubber housing should
not be visibly dented.
12. Reconnect the four (4) compressor wires to the
power supply cable (Figure 5):
a. Connect the brown wire to the overload relay.
b. Connect the gray wire from the power supply
to the blue wire from the capacitor and relay
assembly.
c. Connect the black wire from the power
supply to a black wire from the heater.
11
d. With the
/
" wrench, connect the green/
32
yellow ground wire with the nut to the
threaded standoff on the frame.
13. Reinstall the terminal cover onto the
compressor.
14. Connect the green/yellow ground wire from the
module chassis to the compressor with the
included screw and lock washer.
CAUTION
Earth ground bonding conductor. Ensure that
the green/yellow wire is reconnected to this
terminal.
15. Slide the refrigeration module to the rear of the
refrigerator and place the drain tube in the drip
pan on the module (Figure 9).
Figure 9: Position drain tube in front half of the drip
pan
16. Ensure the black gasket is aligned and gasket
nubs are inserted in corresponding holes on the
frame of the refrigerator module (Figure 10).

Advertisement