Place the insert on the hearth and carefully slide it into the
fireplace. Be sure the gas line enters the heater through the gas
access opening and that the electrical cord is hanging out the
front of the fireplace.
Position any excess flex vent pipe back up into the chimney. Slide
the collar bracket under the lances. See Figure 4. Using handle
on Collar Bracket, pull Collar Bracket and slide unit back. Secure
the Collar Bracket with the [2] screws removed earlier.
Attach the pipe-to-cap adapter to the termination cap and to the
top of the flexible vent pipe and set the cap in place at the top of
the chimney. Attach the labeled vent pipe to the labeled collar on
the termination. See Figure 5.
Figures 6 and 7 show typical installations of the appliance.
NOTE:
To avoid down drafts and/or cold air
problems, it is recommended to seal off the
area between the termination cap and the top
of the solid-fuel chimney opening into which
the vent cap has been installed.
f i r e - p a r t s . c o m
Figure 4 - Reinstalling the Starter Collar
Termination
Cap
Exhaust
Collar
Figure 5
8/00
i30SE Direct Vent Gas-Fired Insert (Firebox Only)
Insulation
Adaptor
Inlet
Air Collar
Exhaust
Air Vent
Pipe
WARNING!
The exhaust pipe must only be connected
to the exhaust starting collar of the unit and
the center collar of the termination cap.
The inlet air pipe must only be connected
to the inlet air collar of the unit and
either attached to the inlet air collar of
the termination cap or terminated in the
chimney.
THIS FIREPLACE HAS BEEN ALTERED TO ACCOMMODATE
AN INSERT AND SHOULD BE INSPECTED BY A QUALIFIED
PERSON PRIOR TO RE-USE AS A CONVENTIONAL
FIREPLACE.
Note:
The above label, located in the instruc-
tion package, must be affixed to the existing
fireplace prior to installation of the i30SE Direct
Vent Gas-Fired Heater.
8
Termination Cap
Adaptor
V=14 ft. Minimum
40 ft. Maximum
Inlet Air
Vent Pipe
Figure 6