  • Page 3 Safety information Read and follow all safety instructions DANGER in this manual to avoid unsafe operating conditions, property damage, personal • Do not supply 230 VAC to this device. injury, or death. Doing so may result in fire, severe personal injury, or death. Safety messages used in this manual DANGER...
  • Page 4 You may damage the device. devices. Consult the manufacturers Any attempt to disassemble or of your electronic devices to solve repair the device voids Navien’s any interference problems you Limited Warranty. Navien is not experience. responsible for damage or injuries caused by voiding the Navien’s...
  • Page 5 CAUTION • Do not use loose or damaged cables. This may result in a poor • Use suitable tools and appropriate connection or cause the device to force to install the device. malfunction. Using unsuitable tools or excessive • This device has been approved for force during installation may use in the UK and EU only.
  • Page 6: Table Of Contents

    Contents Overview ......7 Resetting the connection data ........21 Supplied items ........9 Resetting Wi-Fi connection data ..21 Device layout ........10 Resetting RF connection data ..21 Resetting the Wi-Fi and RF connection data simultaneously ..21 Installing the wireless communication module..13 Connecting the KIW Troubleshooting ....
  • Page 7: Overview

    Navien Smart Plus uses 2-way communication on an 868 MHz radio frequency (RF) band to control the heating system. The wireless communication module (BCM-40RW) operates as the control centre of the system, and the Navien boilers (LCB700 or NCB-CE) support 2-wire communication (KIW) technology. It is possible to control it using a 2-wire connection from the BCM-40RW terminals.
  • Page 8 NRC-10R LCB700 NCB-CE VCU-10R Comm BCM-40RW Navien boiler • This device specifications or contents of this manual may be changed without prior notice due to upgrade of device functions. • The device functions can be limited by the operating environment.
  • Page 9: Supplied Items

    Supplied items Open the packaging and ensure that the following items are provided. Wireless communication Screws and anchors Wall mounting plate module Installation & Operation Extension cable manual...
  • Page 10: Device Layout

    Device layout The following table provides the brief information on each part of the wireless communication module. No Name Description Wi-Fi Press and hold to enter or exit Wi-Fi AP mode. button Press and hold to enter or exit RF pairing mode. button Insert the tip of a sharp object to reset the RF or Wi-Fi connection data.
  • Page 11 No Name Description Indicates the Wi-Fi operation (AP mode) status. Status Description Colour • The wireless communication module is booting for Wi-Fi communication. • There is no Wi-Fi network connected to the wireless communication module. • The Wi-Fi AP mode is turned off. Blinking The device is in Wi-Fi AP mode.
  • Page 12 No Name Description Indicates the RF operation status between the wireless communication module and paired RF devices. Status Description Colour • The wireless communication module is booting for RF communication. • There are no devices paired with the wireless communication module. •...
  • Page 13: Installing The Wireless Communication Module

    Installing the wireless communication module Connecting the KIW Connect the KIW communication cable from the boiler to the wireless communication cable communication module and install it on a wall near the boiler as the boiler The KIW communication cable from provides power for the communication the boiler must be connected to the module.
  • Page 14 Connect one end of the extension cable to the port on the front panel of the boiler and the end of the extension cable to one end of the KIW communication cable from the wireless communication module. <For NCB-CE boilers> <For LCB700 boilers>...
  • Page 15 Pass one end of the KIW Connect the KIW communication communication cable from the cable to the wireless communication boiler through the hole in the wall module’s power terminal block on mounting plate. the wall mounting plate.
  • Page 16: Attaching The Wall Mounting Plate

    Attaching the wall mounting Hang the wireless communication module on the wall mounting plate plate by aligning the hooks. You will hear a "click" sound when Check the direction of the wall the wireless communication module mounting plate and affix it to the is securely hung.
  • Page 17: Pairing With The Rf Receivers

    Pairing with the RF receivers When pairing the wireless • For the best RF system communication module with the RF performance, install the wireless receivers, such as the wiring centre or communication module in an wireless thermostat, the devices should open area so that it can pair with be in pairing mode.
  • Page 18 Turn on the power to the wireless Press and hold the RF button to exit communication module. pairing mode, and then check if the RF devices are paired with the Press and hold the RF button to enter wireless communication module by pairing mode.
  • Page 19: Connecting To A Wi-Fi Network (For App Use)

    Navien Smart Plus app on your smartphone. For more detailed information on using the app, refer to the Navien Smart Plus app User Manual. Turn on the power to the wireless • To cancel or end AP mode, press communication module.
  • Page 20 Tap Navien_Smart+_XXXX in the From the Wi-Fi network list, select Wi-Fi settings to connect, and then the available Wi-Fi network and enter tap Next. the password. U+ village Home Wi-Fi Navien_Smart+_XXXX Office 123 Navien_Smart+_XXXX Wireless Hub KD thermostat KD wiring centre Router 1 Router 2 If your smartphone has connected...
  • Page 21: Resetting The Connection Data

    Resetting the connection data Resetting Wi-Fi connection data To reset the Wi-Fi connection data, press and hold the Wi-Fi button and the Reset button at the same time. Resetting RF connection data To reset the RF connection data, press and hold the RF button and Reset button at the same time.
  • Page 22: Troubleshooting

    Troubleshooting Before reporting a malfunctioning device, refer to the following table and see if you can identify and fix the problem. Fault situation Suggested Remedies No devices are paired with the wireless communication module. The RF LED status is Check if the RF devices to be paired with the wireless turned red.
  • Page 23 Fault situation Suggested Remedies The Wi-Fi network you have selected from the Wi-Fi network list is providing a poor connection. The Wi-Fi LED status _ Try selecting the Wi-Fi network with an available blinks green and red. connection again. There is no Wi-Fi network connection available, or the Wi-Fi network near the communication module is providing a The Wi-Fi LED status poor connection.
  • Page 24: Recycling And Disposal

    Recycling and disposal Recycling the package Sort out the waste to separate that which can be recycled (cartons, plastics, etc.) from the various wastes that cannot be recycled (straps, etc.). Also recycle the product’s packaging in accordance with all relevant local regulations. WEEE: Recycling or disposing of the device and its parts •...
  • Page 25: Warranty

    Warranty Manufacturer's warranty of 2 years is provided.
  • Page 26: Specifications

    865.15 MHz‒867.95 MHz Wi-Fi 2.4 GHz, IEEE Std. 802.11b/g/n (20 MHz) Permissible operating temperature 0℃‒40℃ Supplier's name: KDEL (KYUNGDONG ELECTRONICS CO., Ltd.) Supplier's model identifier: BCM-40RW (Wireless communication module) ErP control Space heating Description class energy efficiency Weather compensator and room sensor, for use...