1-2. SUMMARY OF SYSTEM COMPONENTS

Components
1. Outdoor units
Corresponding HP
Cooling only MMY- MP0801T8
Model
Heat pump
MMY- M P 0 801H T 8
name
Heat pump
MMY- M P 0 801H T 7
Cooling capacity (kW)
Heating capacity (kW)
2. Outdoor units (Combination of outdoor units)
Corresponding HP
8 HP
MMY- MP0801T8
Combined
MMY- MP0801HT8 MP1001HT8 P1401HT8
Model
MMY- MP0801HT7 MP1001HT7 P1401HT7
Cooling capacity (kW)
22.4
Heating capacity (kW)
25.0
Inverter unit
8 HP
Combined
outdoor
Fixed-
units
speed unit
No. of connectable
13
indoor units
Corresponding HP
30 HP
MMY-
P3001T8
Combined
MMY- P3001HT8
Model
MMY- P3001HT7
Cooling capacity (kW)
85.0
Heating capacity (kW)
94.5
Inverter unit
10 HP
10 HP
Combined
outdoor
10 HP
Fixed-
units
speed unit
No. of connectable
30
indoor units
3. Branching joints and headers
Model name
RBM-BY52E
RBM-BY102E
Y-shape branching
joint (*3)
RBM-BY202E
RBM-BY302E
RBM-HY1042E Indoor unit capacity code (*1) : Total below 13.2
4-branching header
(*4)
RBM-HY2042E Indoor unit capacity code (*1) : Total 13.2 or more and below 25.2
RBM-HY1082E Indoor unit capacity code (*1) : Total below 13.2
8-branching header
(*4) (*5)
RBM-HY2082E Indoor unit capacity code (*1) : Total 13.2 or more and below 25.2
T-shape branching
joint
RBM-BT12E
(For connection of
outdoor units)
1 "Capacity code" can be obtained from page 1-12. (Capacity code is not actual capacity)
*
2 If total capacity code value of indoor unit exceeds that of outdoor unit, apply capacity code of outdoor unit.
*
3 When using Y-shape branching joint for 1st branching, select according to capacity code of outdoor unit.
*
*
4 Max. 6.0 capacity code in total can be connected.
5 If capacity code of outdoor unit is 26 and more, it is not used for 1st branching.
*
6 Model names for outdoor and indoor units described in this guide are shortened because of the space constraint.
*
Inverter unit
8 HP
10 HP
6 HP
MP1001T8
MP06018
M P 1 001H T 8 MP0601H8 MP0801H8 MP1001H8
M P 1 001H T 7 MP0601H7 MP0801H7 MP1001H7
22.4
28.0
16.0
25.0
31.5
18.0
10 HP
14 HP
16 HP
MP1001T8
P1401T8
P1601T8
P1601HT8
P1601HT7
28.0
38.4
31.5
43.0
10 HP
8 HP
8 HP
6 HP
8 HP
16
16
32 HP
34 HP
36 HP
P3201T8
P3401T8
P3601T8
P3201HT8
P3401HT8
P3601HT8
P3201HT7
P3401HT7
P3601HT7
90.0
95.2
102.4
109.0
115.5
119.0
8 HP
10 HP
10 HP
8 HP
8 HP
10 HP
8 HP
8 HP
8 HP
8 HP
8 HP
8 HP
32
34
Indoor unit capacity code (*1) : Total below 6.4
Indoor unit capacity code (*1) : Total 6.4 or more and below 13.2
Indoor unit capacity code (*1) : Total 13.2 or more and below 25.2
Indoor unit capacity code (*1) : Total 25.2 or more
1 set of 3 types of T-shape joint pipes as described below:
The required quantity is arranged and they are combined at the site.
Connection piping
Balance pipe
Piping at liquid side
Piping at gas side
Fixed-speed unit
8 HP
10 HP
MP08018
MP10018
22.4
28.0
28.0
31.5
18 HP
20 HP
P1801T8
P2001T8
P1801HT8
P2001HT8
P1801HT7
P2001HT7
45.0
50.4
56.0
53.0
59.5
63.0
10 HP
10 HP
8 HP
10 HP
18
18
20
38 HP
40 HP
P3801T8
P4001T8
P3801HT8
P4001HT8
P3801HT7
P4001HT7
106.4
112.0
122.5
126.0
10 HP
10 HP
10 HP
10 HP
10 HP
10 HP
8 HP
10 HP
36
38
40
Usage
Corresponded dia. (mm)
Ø9.52
Ø12.7 to Ø25.4
Ø25.4 to Ø50.8
1-3
Appearance
22 HP
24 HP
26 HP
P2201T8
P2401T8
P2601T8
P2201HT8
P2401HT8
P2601HT8
P2201HT7
P2401HT7
P2601HT7
63.0
69.0
73.0
71.0
81.0
87.5
8 HP
8 HP
10 HP
8 HP
8 HP
8 HP
6 HP
8 HP
8 HP
22
24
26
42 HP
44 HP
46 HP
P4201T8
P4401T8
P4601T8
P4201HT8
P4401HT8
P4601HT8
P4201HT7
P4401HT7
P4601HT7
117.6
123.2
128.8
143.5
147.0
150.5
10 HP
10 HP
10 HP
8 HP
10 HP
10 HP
8 HP
8 HP
10 HP
8 HP
8 HP
8 HP
8 HP
8 HP
8 HP
40
40
40
Appearance
(*2)
(*2)
(*2)
Max.4
branches
Max.8
branches
Q'ty
1
1
1
28 HP
P2801T8
P2801HT8
P2801HT7
80.0
91.0
10 HP
10 HP
8 HP
28