Toshiba ETB003Z Instruction Manual page 4

Expansion io card option 1
Table of Contents

Advertisement

■ Wiring
▼ Electrical construction work must be done by a qualified expert.
Installation or connection of input power by someone who does not have that expert
knowledge may result in fire or electric shock.
▼ Shut off power when installing and wiring this option.
Wait at least 15 minutes and check to make sure that the charge lamp (VF-AS1/PS1)
Mandatory
is no longer lit.
▼ Tighten the screws on the terminal block to the specified torque (Refer to Section 2.2).
If the screws are not tightened to the specified torque, it may lead to fire.
■ Operations
▼ Do not pull on any cable itself.
Doing so could result in damage or malfunction.
▼ Do not touch switches when the hands are wet and do not try to clean the inverter with
Prohibited
a damp cloth.
Doing so could result in electric shock.
▼ Use this option under the environment specified in the instruction manual.
Usage under the environment other than them may cause damages or malfunctions or
an accident.
▼ Use an additional safety device with your VF-AS1/PS1 or system to prevent a serious
Mandatory
accident due to the unit malfunctions.
Usage without an additional safety device may cause an accident.
■ Disposal
▼ For safety's sake, do not dispose of the disused inverter yourself but ask an industrial
waste disposal agent (*).
If the collection, transport and disposal of industrial waste is done by someone who is
not licensed for that job, it is a punishable violation of the law. (Laws in regard to
Mandatory
cleaning and processing of waste materials)
(*) Persons who specialize in the processing of waste and known as "industrial waste
product collectors and transporters" or "industrial waste disposal persons."
Notes on use
▼ Do not install the inverter where the temperature or the humidity will change rapidly.
▼ Keep a distance of 20cm or more between the inverter's power cable and the data
transmission cable.
Or the inverter might malfunction because of noise.
▼ Insert a magnetic contactor or similar device between the VF-AS1/PS1 and the power
supply to ensure that power is turned off if an emergency stop command is entered
through the network.
Caution
Warning
Caution
Notes
3
E6581339⑥

Advertisement

Table of Contents
loading

Table of Contents