GE PFE29PSDASS Manual page 89

Table of Contents

Advertisement

Post Dwell Cycle
Upon completion of the dwell cycle, the unit will enter the post dwell cycle.
The 3-way valve will move to either the 'A' or 'B' position, depending upon
whether the fresh food temperature is satisfied.
The compressor and condenser fan will start, but the fresh food fan, freezer
fan and ice box fan will remain off.
Post dwell will end when the freezer and fresh food evaporators reach the
post dwell exit temperature of -10˚F*, or the post dwell time of
10*
minutes
has expired.
Upon exit of post dwell, the control system will now operate all cooling
components by it's logic and restarts the compressor run timer for adaptive
defrost.
* Values are approximate and preliminary
89