Description of Hand Dryer
The sole purpose of the hand dryer is to dry hands. The hands are dried in a stream of warm air
that flows out of the air outlet grille. The hands can be rubbed together to accelerate drying.
The hand dryer is operated by a proximity switch which starts the unit automatically when hands
are placed under the air outlet grille. When the hands are removed from the airflow, the proximity
switch automatically stops the dryer after a run-on delay of approximately 2 seconds.
The hand dryer is designed to be mounted indoors only.
It must be mounted on a vertical wall with the air outlet opening pointing downwards. The
appliance should only be connected to the fixed wiring of the premises.
The installation and electrical connection of the hand dryer may only be performed by a
competent electrician!
All safety measures taken must conform to the applicable national regulations effective in the
relevant country! The electrical supply circuit to the dryer must incorporate an isolating switch
with at least 3mm contact clearance on each pole!

Technical Specifications

Type
Operating voltage
Rated power
Enclosure protection level
Class of protection
Type of connection
Type of mounting
Operation
Time delay
Airflow rate
Noise level
Dimensions W x H x D
Weight
Materials supplied with hand dryer
The hand dryer comes complete with a drilling template, special spanner and mounting
hardware.
HD 501 AK
220-240 V~ 50/60 Hz
1640 W
IP 21
II, double insulated
Fixed connection
Wall mounting
Proximity switch
2 seconds
3
280 m
/h
60 dB (2 m)
253 x 302 x 149 mm
3.0 kg
Subject to change without notice
5
hd501-601_ba 06/08/C
HD 601 AM
220-240 V~ 50/60 Hz
1640 W
IP 21
II, double insulated
Fixed connection
Wall mounting
Proximity switch
2 seconds
3
280 m
/h
60 dB (2 m)
255 x 302 x 140 mm
4.4 kg

Advertisement