Trouble Shooting
Error Type
Error Mode
„Heavy‟ +
Thermistor Error
„Delicate‟ +
„Quick‟ LED
Checking Method
1. Check the connections for the Thermistor
connector.
2. Check whether the Thermistor is operating normally.
- Measure the voltage between both ends of the
Thermistor.
➢ Normal: 0.2 to 4.5V
- Measure the resistance between both ends of the
Thermistor:
Remove the connector before measuring.
(See the Table right.)
Corrective actions
- Reconnect the Thermistor connector.
- Faulty: Replace the Thermistor.
- Normal: Replace the Main PBA assy.