Pentair Schroff 24579-604 User Manual

Cpci case system 3/4 u

Advertisement

Quick Links

CPCI Case System 3/4 U
User's Manual
Product No.:
24579-604
August 03, 2011
Doc-No: 63972-309_R1.0

Advertisement

Table of Contents
loading

Summary of Contents for Pentair Schroff 24579-604

  • Page 1 CPCI Case System 3/4 U User’s Manual Product No.: 24579-604 August 03, 2011 Doc-No: 63972-309_R1.0...
  • Page 2 Rev. Date updated Change R1.0 August 03, 2011 Initial Release Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this manual have been carefully compiled and checked - supported by certified Quality Management System to EN ISO 9001/2000 The company cannot accept any liability for errors or misprints. The company reserves the right to amendments of technical specifications due to further development and improvement of products.
  • Page 3: Table Of Contents

    CPCI Case System 3/4 U 24579-604 Table of Contents Safety ......................... 1 Intended Application .................... 1 Safety Instructions ....................2 1.2.1 Safety Symbols used in this document ..........2 General Safety Precautions................. 2 Product Definition..................... 3 References and Architecture Specifications ............3 Case System Overview ..................
  • Page 4 CPCI Case System 3/4 U 24579-604 www.schroff.biz R1.0, August 03, 2011...
  • Page 5: Safety

    CPCI Case System 3/4 U Safety 24579-604 1 Safety 1.1 Intended Application The CompactPCI (CPCI) case system, described in this manual, is intended as a platform for a microcomputer system based on the CompactPCI Standard PICMG 2.0 Rev.3. The CPCI case systems are designed for protection class IP 20 and can be used only in the resp.
  • Page 6: Safety Instructions

    CPCI Case System 3/4 U Safety 24579-604 1.2 Safety Instructions The intended audience of this User’s Manual is system integrators and hardware/software engineers. 1.2.1 Safety Symbols used in this document Hazardous voltage! This is the electrical hazard symbol. Familiarise yourself with the danger of electrical voltages and the safety precautions to avoid accidents before starting to work with parts that carry dangerous voltages.
  • Page 7: Product Definition

    CPCI Case System 3/4 U Product Definition 24579-604 2 Product Definition The Schroff CPCI case system consists of: • A shielded ratiopacPRO-air case with front and rear card cage for 3 U boards according to CompactPCI Standard PICMG 2.0 Rev.3 •...
  • Page 8: Case

    CPCI Case System 3/4 U Product Definition 24579-604 2.3 Case The 4 U case is based on the Schroff ratiopacPRO-air system with EMC shielding. The card cage enables the assembly of 8 CPCI front boards (3 U, 4 HP, 160 mm deep) and 8 Rear I/O Boards (3 U, 4 HP, 80 mm deep). The lower guide rails of the card cage are equipped with ESD clips.
  • Page 9: Power Supply

    CPCI Case System 3/4 U Product Definition 24579-604 2.6 Power Supply Hazardous voltage! Parts of the power supply may be exposed with hazardous voltage. Always remove mains/line connector before carry out any assembly work. Caution! Your system has not been provided with a AC power cable. Purchase a AC power cable that is approved for use in your country.
  • Page 10: Cpci Plug-In Ac Power Supply

    CPCI Case System 3/4 U Product Definition 24579-604 2.6.1 CPCI Plug-In AC Power Supply Figure 3: Power Supply 10006814 Table 1: Data AC Power Supply Input voltage nominal 100 - 240 VAC Mains Frequency 50 / 60 Hz Output (max.) 250 W Output voltages 12.0...
  • Page 11: Cooling

    CPCI Case System 3/4 U Product Definition 24579-604 2.7 Cooling The CPCI boards are cooled by forced air convection through two 12 VDC radial fans (36 m³/h (21 cfm)). The operating temperature is from 0°C to 50°C. Caution! To maintain proper airflow, all open slots must be covered with filler panels. The filler panel should include an airflow baffle that extends to backplane.
  • Page 12: Installation

    CPCI Case System 3/4 U Installation 24579-604 3 Installation 3.1 General Installation Guidelines 3.1.1 Unpacking Caution! When opening the shipping carton, use caution to avoid damaging the system. Consider the following when unpacking and storing the system: • Leave the system packed until it is needed for immediate installation. •...
  • Page 13: Service

    CPCI Case System 3/4 U Service 24579-604 4 Service 4.1 Technical support and Return for Service Assistance We generally recommend to return the complete system. For all product returns and support issues, please contact your Schroff sales distributor or www.schroff.biz. We recommend that you save the packing material.
  • Page 14: Scope Of Delivery

    CPCI Case System 3/4 U Service 24579-604 4.3 Scope of Delivery Quantity Description ratiopacPRO-air case 4 U / 44 HP, shielded, powder coated (RAL9006/RAL7016) CPCI backplane (PICMG2.0 R.3.0), 8 slot 3 U Power backplane with P47 connector Front card cage for max. 8 boards 3 U 160 mm deep IEEE guide rails inc.
  • Page 15: Technical Data

    CPCI Case System 3/4 U Technical Data 24579-604 5 Technical Data Table 2: Technical Data Dimensions Height (w/o feet) 177 mm (4 U) Height (with feet) 192,2 mm Width (with handles 44 HP (258,9 mm) Depth (Card cage) 275 mm Depth (Overall with handles) 340,49 mm Weight...
  • Page 16: Dimensions

    CPCI Case System 3/4 U Dimensions 24579-604 6 Dimensions Figure 5: Dimensions www.schroff.biz R1.0, August 03, 2011...
  • Page 18 SCHROFF GMBH www.schroff.biz Langenalberstr. 96-100 Tel.: + 49 (0) 7082 794-0 Fax: +49 (0) 7082 794-200 D-75334 Straubenhardt...