Mitsubishi Electric PFAV-P250VM-E Operation Manual
Mitsubishi Electric PFAV-P250VM-E Operation Manual

Mitsubishi Electric PFAV-P250VM-E Operation Manual

Indoor unit
Hide thumbs Also See for PFAV-P250VM-E:

Advertisement

Quick Links

Air-Conditioners
INDOOR UNIT
PFAV-P250·500·750VM-E
PFAV-P300·600·900VM-E-F
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du climatiseur.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro della stessa.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado.
IŞLETME ELKİTABI
Emniyetli ve doğru biçimde nasıl kullanılacağını öğrenmek için lütfen klima cihazını işletmeden önce bu elkitabını dikkatle okuyunuz.
HASZNÁLATI KÉZIKÖNYV
A megfeleő és biztonságos használat érdekében, kérjük, hogy figyelmesen olvassa el a használati kézikönyvben leírtakat a légkondicionáló berendezés üzembe helyezése előtt.

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PFAV-P250VM-E

  • Page 1 Air-Conditioners INDOOR UNIT PFAV-P250·500·750VM-E PFAV-P300·600·900VM-E-F OPERATION MANUAL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen. MANUEL D’UTILISATION Pour une utilisation correcte sans risques, veuillez lire le manuel d’utilisation en entier avant de vous servir du climatiseur. MANUAL DE INSTRUCCIONES Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto.
  • Page 2 Remote Controller Display Section [Fig. 2.1] “Sensor” indication For purposes of this explanation, all parts of the display are shown as lit. During actual operation, only the relevant items will be lit. “Locked” indicator Day-of-Week Time/Timer Display Identifies the current operation “Clean The Filter”...
  • Page 3 Indoor Unit [Fig. 2.3] PFAV-P250·500VM-E K Air outlet louver L Outlet * Optional parts C Front top panel D Operation section (MA remote controller) E Side panel M Inlet F Drain pipe hole N Return air panel B Electrical components box G Air filter H Earth screw (in the electrical components box) O Outlet (on top)
  • Page 4: Table Of Contents

    • Check frequently that the ground wire from the outdoor unit is properly • Use only accessories authorized by Mitsubishi Electric and ask your connected to both the unit’s ground terminal and the grounding dealer or an authorized company to install them.
  • Page 5: Disposing Of The Unit

    • Ensure that the drain trap is properly water-sealed. Caution: - If the drain trap is modified, or is not water-sealed, the trap will not function • Do not direct the airflow at plants or caged pets. and a water leak may occur. Inject water into the hose during the periodic •...
  • Page 6: How To Operate

    3. How to Operate The use of the sensor can be switched between on the indoor unit and on the remote controller. The factory setting is the sensor on the indoor unit. Refer to the Installation Manual for switching the sensor. 3.1.
  • Page 7 3. Using the Timer <Room Temperature Display> During operation, the intake temperature is shown at 4. This section explains how to set and use the timer. You can use Function When using the supply air temperature sensor, the supply air temperature is Selection of remote controller to select which of three types of timer to use: shown at 4.
  • Page 8 <Setting the Weekly Timer> 2 Using the Simple Timer You can set the simple timer in any of three ways. Shows the time setting Shows the selected operation (ON or OFF) • Start time only: The air conditioner starts when the set time has elapsed. * Does not appear if operation is not set.
  • Page 9 <Viewing the Current Simple Timer Settings> 3 Using the Auto Off Timer This timer begins countdown when the air conditioner starts, and shuts the air Timer Setting conditioner off when the set time has elapsed. Available settings run from 30 minutes to 4 hours, in 30-minute intervals. TIMER Note: AFTER...
  • Page 10 <To Turn Off the Auto Off Timer...> <How to Unlock the Buttons> Hold down the Timer On/Off button 9 for 3 seconds, so that “TIMER MODE 1. While holding down the Filter button 4, press and hold down the ON/OFF OFF”...
  • Page 11 <Flashing Error Codes> ERROR CODE ON lamp ON/OFF (Flashing) Error Code Indoor Unit No. If you have entered contact number to be called in the event of a problem, the screen displays this number. (You can set this up under Function Selection of remote controller. For information, refer to section 3.4.) If the ON lamp and error code are both flashing: This means that the air conditioner is out of order and operation has been stopped (and cannot...
  • Page 12: Function Selection

    3.4. Function Selection Function selection of remote controller The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting when needed. Item 1 Item 2 Item 3 (Setting content) 1. Change Language Language setting to display •...
  • Page 13: Ventilation Setting

    [Detailed setting] • Setting the contact numbers To set the contact numbers, follow the following procedures. [4]–1. CHANGE LANGUAGE setting Move the flashing cursor to set numbers. Press the [ TEMP. ( ) and The language that appears on the dot display can be selected. )] button F to move the cursor to the right (left).
  • Page 14: Remote Controller Specifications

    6 Set the address of the LOSSNAY you want to register using the [ CLOCK a Press the [ ON/OFF] button twice and delete registration of the LOSSNAY ) and ( )] buttons. (01 to 50) registered at the set indoor unit. - Deletion end display Indoor unit address and “–...
  • Page 15: Self Check

    2. In Case of Communication Circuit Failure or Error codes for which emergency operation is possible (common to OC and OS) Power OFF Error with Some Outdoor Units Error codes for which Failure location emergency operation is Error code details •...
  • Page 16: Remote Controller Check

    When the [ MENU] button is pressed twice successively within three seconds, When the error history was reset, the display shown below appears. the self check address or refrigerant address flashes. When error history reset failed, the error contents are displayed again. ERROR CODE 5 Self check reset There are the following two ways of resetting self check.
  • Page 17: The Smart Way To Use

    4. The Smart Way to Use Prevent intrusion of heat during air-cooling Even minimal steps to care for your unit can help make its use far more effective in terms of air-conditioning effect, electricity charges, etc. • To prevent the intrusion of heat during cooling operation, provide a curtain or a blind on the window to block out direct sunlight.
  • Page 18: Installation, Transferring Works, And Checking

    The following do not indicate any malfunction: NOTE: The refrigerant charged in the air conditioner is safe. Refrigerant Odours: smells such as tobacco or cosmetic odours may persist after they have normally does not leak, however, if refrigerant gas leaks indoors, been sucked into the unit.
  • Page 19: Cleaning The Indoor Unit Heat Exchanger

    (5) Turn the power supply on before 12 hours or more. (3) Check that the earth wire is connected. The earth wire may be connected with the indoor unit as well in some cases. 12. Specifications <PFAV-P·VM-E series> Model PFAV-P250VM-E PFAV-P500VM-E PFAV-P750VM-E Item Power source 3N~/380V/400V/415V 50Hz/60Hz Cooling capacity*1 25.0...
  • Page 20: Warranty And Servicing

    13. Warranty and Servicing Periodic maintenance and checks by an authorized service person are required to ensure that the unit is maintained in a good condition for a long period of time, and that it may be used with confidence. Check Frequency for the standard maintenance and checks, and the Maintenance Frequency associated with periodic checks are as follows.
  • Page 21 This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is • Low Voltage Directive 2006/95/EC based on the following • Electromagnetic Compatibility Directive EU regulations: 2004/108/EC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

Table of Contents