Product
AXIS Q6042-E Mk II
AXIS Q6044-E
AXIS Q6045-E Mk II
* Arctic Temperature Control enables camera start-up at temperatures as low as -50 °C (-58 °F)

Storage Conditions

The Axis product is intended for outdoor use.
Product
AXIS Q6042-E Mk II
AXIS Q6044-E
AXIS Q6045-E Mk II

Power Consumption

NO TICE
TICE
NO
NO
TICE
Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either
a rated output power limited to ≤100 W or a rated output current limited to ≤5 A. Axis
recommends using the supplied midspan.
Product
AXIS Q6042-E Mk II
AXIS Q6044-E
AXIS Q6045-E Mk II

Install the hardware

Read all the instructions before installing the product. Some installation steps would benefit from
being completed together because they require removal of the dome cover.
NO
NO TICE
NO
TICE
TICE
• The product shall be connected using a shielded network cable (STP). All cables connecting
the product to the network shall be intended for their specific use. Make sure that the
Classification
Temperature
IEC 60721-4-3
-50 °C to 50 °C
Class 3K3, 3M3
(-58 °F to 122 °F)*
IEC 60529 IP66
Temperature
-50 ºC to 60 ºC (-58 ºF to 140 ºF)
High PoE
Max 60 W
Humidity
10–100% RH (condensing)
Axis High PoE midspan
(included)
100–240 V AC,
max 53 W,
typical 15.3 W
100–240 V AC, max 74 W