Lennox Elite Series Care And Operation Instructions Manual page 6

B-vent gas fireplace heater inserts
Table of Contents

Advertisement

6. (Model EBVI25) Remove the two hex
head bolts shown in Figure 7.
(Model EBVI30) Remove the two
screws shown in Figure 8, then lift
out air duct channel.
Model EBVI25
Remove  Bolts
Blower
Figure 7
Model EBVI30
Remove  Screws
Lift Out Air
Duct Channel
Figure 8
6
7. Disconnect wires from the blower.
8. Lift blower up and pull it out from back
opening of firebox (see Figure 9).
9. To reinstall blower, reverse Steps 1
through 8.
Blower Assembly
Figure 9
Small Area Paint Touch-up
The finish of the insert body and surround
(optional) is a high-quality powdercoat. Only
use factory supplied powdercoat paint kit for
touch-ups, cat. no. 90L74.
Do not attempt to repaint the insert until the
finish is completely cured (see Burn-In Period
on Page 4). If the surface later becomes stained
or marred, it may be lightly sanded and touched
up with spray paint.
Paint is available at your local authorized Lennox
Hearth Products dealer. Never attempt to paint
a hot insert.
Inspect Wiring
Inspect and clean all wire connections. Ensure
that there is no melting or damage. Inspection
should include:
• Terminals at the valve
• Off/On switch
• Wall thermostat, remote control, or control
kit (optional parts)
• Spill switch
Refer to wiring diagrams on Pages 12 & 13.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
CAUTION
Label all wires prior to discon-
nection when servicing con-
trols. Wiring errors can cause
improper and dangerous appli-
ance operation.
Draft Hood
Check
Connections
Spill Switch
Figure 10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite ebvi25Elite ebvi30

Table of Contents