Model Designation; Maximum Camera/Lens Size; Tools Required; Cable Requirements - Philips LTC 9483/00 Installation Instructions Manual

Unity line housings
Table of Contents

Advertisement

6.1

Model Designation

Model
Preinstalled
No.
Heater or
Heater/Blower
Indoor Units
LTC 9480/00
---
Outdoor Units
LTC 9483/00
---
LTC 9488/00
---
LTC 9483/20
Heater
LTC 9483/21
Heater/Blower
LTC 9483/50
Heater
LTC 9483/60
Heater
LTC 9483/61
Heater/Blower
LTC 9488/20
Heater
LTC 9488/21
Heater/Blower
LTC 9488/50
Heater
LTC 9488/60
Heater
LTC 9488/61
Heater/Blower
1. The heaters and blowers for all models operate at 50/60 Hz.
Do Not Exceed 30 VAC Input on 24 VAC models. Operation
above 30 VAC violates low voltage operation (Class 2
Specifications). Normal operation is 24 VAC.
TUV Approved 24 VAC Models
Caution: Use an approved power supply incorporating
reinforced insulation from primary to secondary to isolate unit
from Mains.
6.2

Maximum Camera/Lens Size

LTC 9480/00: 68 W x 54 H x 197 L mm (2.68 x 2.1 x 7.75 in)
LTC 9483/00: 68 W x 54 H x 267 L mm (2.68 x 2.1 x 10.5 in)
LTC 9483/20: 68 W x 54 H x 267 L mm (2.68 x 2.1 x 10.5 in)
LTC 9483/50: 68 W x 54 H x 267 L mm (2.68 x 2.1 x 10.5 in)
LTC 9483/60: 68 W x 54 H x 267 L mm (2.68 x 2.1 x 10.5 in)
LTC 9483/21: 68 W x 54 H x 216 L mm (2.68 x 2.1 x 8.5 in)
LTC 9483/51: 68 W x 54 H x 216 L mm (2.68 x 2.1 x 8.5 in)
LTC 9483/61: 68 W x 54 H x 216 L mm (2.68 x 2.1 x 8.5 in)
LTC 9488/00: 71 W x 71 H x 356 L mm (2.8 x 2.8 x 14.0 in)
LTC 9488/20: 71 W x 71 H x 356 L mm (2.8 x 2.8 x 14.0 in)
LTC 9488/50: 71 W x 71 H x 356 L mm (2.8 x 2.8 x 14.0 in)
LTC 9488/60: 71 W x 71 H x 356 L mm (2.8 x 2.8 x 14.0 in)
LTC 9488/21: 71 W x 71 H x 318 L mm (2.8 x 2.8 x 12.5 in)
LTC 9488/51: 71 W x 71 H x 318 L mm (2.8 x 2.8 x 12.5 in)
LTC 9488/61: 71 W x 71 H x 318 L mm (2.8 x 2.8 x 12.5 in)
1. With heater.
2. With heater and blower.
6.3

Tools Required

- Small flat blade screwdriver.
- Phillips screwdriver (P2).
- Adjustable wrench.
- Wire cutter/stripper/crimper tool.
- 5/32-in (or 4 mm) hex wrench.
6.4

Cable Requirements

Video Transmission (Coaxial)
Cable Type:
RG-59/U for runs < 300 m (1000 ft).
RG-11/U for runs < 600 m (2000 ft).
Cable Size:
Outside diameter between
4.6 mm (0.181-in) - 7.9 mm (0.312-in).
Cable Shape:
Round.
Shield:
> 93% Braided Copper Shield.
Center Conductor:
Stranded Copper Center.
DC Resistance:
< 15 Ohms/1000 (RG-59/U).
< 6 Ohms/1000 (RG-11/U).
Cable Impedence:
75 Ohm.
Voltage/
Use with Camera
Power
Models with These
1
V/W
Voltage Ratings
24/0-
24
-----
24, 115, 230
-----
24, 115, 230
24/23
24
24/25
24
230/23
230
115/23
115
115/28
115
24/40
24
24/42
24
230/40
230
115/40
115
115/45
115
1
1
1
2
2
2
1
1
1
2
2
2
Agency Rating:
UL.
Environmental:
Outdoor rated.
Temperature Rating: > 80 °C.
Sources:
Belden 9259.
Belden 9238.
Input Power Cord - North American
Cable Type:
SJTOW-A rated.
Cable Size:
Outside diameter between
4.3 mm (0.170 in) - 11.9 mm (0.470 in).
Cable Shape:
Round.
Conductors:
3 conductor version and
2 conductor version.
Agency Rating:
UL/C.S.A., UL VW-1.
Environmental:
Outdoor rated.
Temperature Rating: 105 °C.
Voltage Rating:
300 V.
Sources:
Belden 19506.
Belden 19509.
Northwire 573939.
Input Power Cord - European
Cable Type:
H05RN-F3G0.75 and
H05RN-F3G1.00.
Cable Size:
Outside diameter between
4.3 mm (0.170 in) - 11.9 mm (0.470 in).
Cable Shape:
Round.
Conductors:
3 conductor version and
2 conductor version.
Agency Rating:
VDE.
Environmental:
Outdoor rated.
Sources:
Olflex 1600252.
Olflex 1600253.
Lens Control Cable
Cable Type:
Jacketed Multiconductor Cable.
Cable Size:
Outside diameter between
4.3 mm (0.170 in) - 11.9 mm (0.470 in).
Cable Shape:
Round.
Shield:
Overall shielding.
Conductors:
Stranded 20 to 16 AWG wire.
No. of Conductors: 4 and 8.
Conductor
Insulation:
Color coded.
Sources:
Belden 9552.
Belden 9554.
6.5

Housing Mounting

1. Use the two 1/4-20 x 0.50-inch screws and 1/4-in spring
washers provided in the hardware kit to mount the housing
to a mount or a pan/tilt. The spring washers must be used
for the screws to thread properly.
2. The outer most set of 1/4-20 threaded holes are for
mounting to feed-through mounts and the inner most 1/4-
20 holes are for mounting to all other mounts and pan/tilts.
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents