SERVICE MANUAL – MODEL TLXG0201S000
USING THE THERMOPRO SERVER
WARNING – THERMOPRO SERVERS MAY BE HEAVY WHEN FILLED. CARE MUST BE TAKEN
WHEN TRANSPORTING TO AVOID DROPPING OR SPILLING.
Use only coffee or water in the insulated dispenser. Do not use the airpot to dispense any other beverage.
Preheating the airpot is recommended.
1. Place a clean and empty server centered under one of the brewcones of the ThermoPro brewer.
2. Make sure the READY TO BREW indicator is lit.
3. Fill brewcone with the correct measure of ground coffee.
4. Press the desired brew button on the side of the brewer with the empty airpot. The ThermoPro airpot
employs the Curtis Brew-Thru lid and it is not necessary to remove the top lid before brewing.
5. Allow the brewcone to completely drip before removing airpot for remote service.
SERVICING AIRPOT/THERMOPRO SERVER
Completely clear the unit of any coffee by opening the faucet to drain over a sink. Unscrew and remove the lid
and tube assembly.
1. REPLACING THE GAUGE GLASS
The gauge glass can be removed for maintenance or to replace if broken.
1. Carefully take hold of the gauge glass guard and lift away the guard from the
front of the unit.
2. The sight glass guard contains two extra glass tubes for replacing a broken
gauge glass. These are held in slots designed into the guard that run the
length of the guard (see fig. 1).
3. Once the gauge glass guard is removed, you will observe that the gauge
glass is held by the black plastic elbow at the top. Pull back on the gauge
glass tube while slightly lifting at the elbow (flexible silicone fitting at the elbow
will allow you to tilt the gauge glass tube). Lift the gauge glass out from the
top of the faucet.
4. The glass tube will come out with a small silicone seal attached, one on each
end. You can pull these off for cleaning (take care to replace the silicone seal
as it was removed, with the large opening sliding over the glass tube).
2. REMOVING THE BASE ASSEMBLY
Remove the base assembly for faucet repair or to move the body of the unit
for placement on a remote serving stand.
1. Remove the wing nut at the centerline of the ThermoPro.
2. Pull tab, left side (fig. 2.).
3. Hold the handle and Twist ¼ turn to lift off of base. Before lifting off the unit,
please notice the mark on the bottom right edge of the airpot marked, "ALIGN
TO INSTALL". This will assist in the assembly of the base and body of the unit.
3. REMOVING THE FAUCET
To replace the faucet or the silicone elbow fitting for repair or cleaning:
1. Remove the base assembly as described above.
2. Remove the Liner Mounting Retainer at the bottom of the liner (held in place by
a black plastic nut). There is a key slot in the stainless body of the unit that aligns
with a pin on the liner retainer for assembly.
W
C
ILBUR
URTIS
C
, I
OMPANY
NC
.

Advertisement

loading

Summary of Contents for Curtis TLXG0201S000

  • Page 1 4. Press the desired brew button on the side of the brewer with the empty airpot. The ThermoPro airpot employs the Curtis Brew-Thru lid and it is not necessary to remove the top lid before brewing. 5. Allow the brewcone to completely drip before removing airpot for remote service.
  • Page 2: Cleaning Instructions

    3. The silicone fitting is held by two wire clamps. Squeeze the wire ears of the clamps to loosen and slide one from the faucet and the other off of the liner drain port. 4. Remove the faucet, unscrew the wing nut and pull out from the front of the unit. 5.
  • Page 3 ThermoPro – 2 Gal Server TLXG0201S000 ILLUSTRATED PARTS LIST ITEM PART Nº Nº DESCRIPTION WC-5673 Lid & Filling Tube Assy TLXG020 WC-3116 Valve, Check W/Ball t O’ Ring TLXG020 WC-3269 Handle, Carrying Black Plastic TLXG020 WC-2425 Fitting, Gauge Glass/Elbow Silicone...
  • Page 4 WARRANTY We hereby certify that the products manufactured by the Wilbur Curtis Company, Inc., are, to the best of our knowledge, free from all defects and faulty workmanship. The following warranties and conditions are applicable: • 2 Year Parts and Labor from Date of Purchase from factory: This warranty covers all fittings and tubing.