3. Installation Space

3.1 General considerations

• If a sunroof is built over the unit to prevent direct sunlight
or rain exposure, make sure that heat radiation from the
heat exchanger is not restricted.
• Ensure that the spaces indicated by arrows around front,
back and side of the unit.
• Do not place animals and plants in the path of the warm
air.
• Take the weight of the unit into account and select a place
where noise and vibration are minimum.
• Select a place so that the warm air and noise from the unit
do not disturb neighbors.
• The surface of the ground or the structure must be strong
enough to bear the weight of the unit.
3 _
Air-to-Water Heat Pump
More than
300mm
F e
n c
o b
e o
s t a
r
c l e
s
More than 700mm
* : Please secure the space to install the shut-off
valve and strainer.
*Minimum
*Minimum
300mm
300mm
*Minimum
300mm
More than 600mm