Installation instructions

for contractors
Vitoplanar wireless receiver
For Vitoplanar wireless thermostat

Safety instructions

Please follow these safety instructions closely to
prevent hazards, injury and material losses.
Safety instructions explained
Danger
¨
This symbol warns against the risk of injury.
!
Caution
This symbol warns against the risk of
material losses and environmental pollution.
Note
Details identified by the word "Note" contain
additional information.
Installation, commissioning, inspection,
maintenance and repairs must only be carried
out by an authorised, competent person (heating
engineer/installation contractor).
5855584 GB 2/2018
VIESMANN

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann Viessmann

  • Page 1: Installation Instructions

    VIESMANN Installation instructions for contractors Vitoplanar wireless receiver For Vitoplanar wireless thermostat Safety instructions Please follow these safety instructions closely to prevent hazards, injury and material losses. Safety instructions explained Danger ¨ This symbol warns against the risk of injury. Caution This symbol warns against the risk of material losses and environmental pollution.
  • Page 2 Repairing components that fulfil a safety function can compromise the safe operation of the system. For replacements, use only original spare parts supplied or approved by Viessmann. Function In conjunction with a Vitoplanar wireless thermostat, the Vitoplanar wireless receiver enables simple switching of heating appliances.
  • Page 3 A Antenna B Control lamp 1 C Control lamp 2 D Button E Cover, removable...
  • Page 4: Before Installation

    Before installation Installation location In the vicinity of the appliance to be switched „ „ (heat generator) A power supply must be available. „ „ Wireless reception must be available. Note the „ „ range. See "Specification". Installation Opening the device...
  • Page 5: Mounting The Device

    Mounting the device Wall mounting To feed the cable through the back panel, break out the pre-punched hole and guide the cable through it. When drilling, watch out for hidden cables.
  • Page 6 Mounting at the back of the appliance to be switched Use the adhesive pads to affix the receiver to a flat surface. Clean the surfaces beforehand. Note Ensure that the button on the device is still accessible.
  • Page 7: Electrical Connection

    Electrical connection Danger ¨ Incorrect wiring can lead to serious injury from electrical current and result in appliance damage. Connections to sockets must only be made by a qualified contractor. Note Ensure that the cores of the power cable are connected correctly! A Power supply B Wireless receiver...
  • Page 8: Closing The Device

    ! Power supply phase ? Power supply neutral conductor § Heating appliance neutral conductor $ Heating appliance switched phase Tighten the strain relief. Closing the device Danger ¨ Electrical current can lead to fatal injury. Close the cover of the device before turning on the power.
  • Page 9 Connecting to the wireless thermostat Press the button on the wireless receiver for longer than 3 seconds until control lamp 1 starts flashing. Now connect the transmitter (wireless thermostat). Wireless thermostat operating instructions Once control lamp 1 on the receiver stops flashing, the devices are assigned.
  • Page 10: Disposal Of Packaging

    The transmitter (wireless thermostat) can now be connected. Disposal of packaging Your contractor will dispose of the packaging from your Viessmann product. DE: Packaging waste is sent to a certified disposal contractor for recycling in line with statutory regulations.
  • Page 11: Specification

    Specification Power supply 230 (50 Hz +/-10 %) Power consumption Breaking capacity Max. 16 Number of receivers Max. 15 Function type Type 1.C (micro switch-off) Radio frequency (standard MHz 868 EN 300 220) Wireless range In a free field Approx. 100 to 300 „...
  • Page 12: Declaration Of Conformity

    Conformity can be found on the following website: DE: www.viessmann.de/eu-conformity AT: www.viessmann.at/eu-conformity CH: www.viessmann.ch/eu-conformity-de www.viessmann.ch/eu-conformity-fr Viessmann Ges.m.b.H. A-4641 Steinhaus bei Wels Telephone: +43 (0)7242 62381-110 Fax: +43 (0)7242 62381-440 www.viessmann.at Viessmann Werke GmbH & Co. KG D-35107 Allendorf Telephone: +49 (0)6452 70-0 Fax: +49 (0)6452 70-2780 www.viessmann.de...