Logging into DSL Circuits
To log into the console menu for an DSL card:
Step
1
In the Main menu screen
and press ENTER. The Enter line unit number field is displayed.
2
Enter a line unit number and press ENTER. The HDSL card console menus display. See the line unit
technical practice for details on console menu usage.
3
To exit the HDSL console menus and return to the TAO Main menu screen, press CTRL+X or select Quit
from the menu (if running HDSL unit firmware version 3.10).
Note:
The V.24 Craft port is disabled on all HDSL cards when an EMU-830 is installed in the shelf. An
HDSL card craft port can be used directly if the EMU-830 is removed from the shelf. The V.24 Craft Port is
enabled on all G.SHDSL line cards.
LTPE-UM-3159-02
AIS
Alarm Indication signal on any G.703
interface
LFA
Loss of Frame alarm on any G.703
interface
RAI
Remote Alarm Indication on any G.703
interface
Action
(Figure 3-3 on page
3-5), type the number 1 in the ENTER SELECTION field
Chapter 3: Provisioning
HDSL
G.SHDSL
HDSL
G.SHDSL
HDSL
G.SHDSL
3-7