Download Print this page
Mitsubishi Electric MSZ-LN09VFV Operating Instructions Manual
Mitsubishi Electric MSZ-LN09VFV Operating Instructions Manual

Mitsubishi Electric MSZ-LN09VFV Operating Instructions Manual

Split-type air conditioners indoor unit

Advertisement

Available languages

Available languages

Quick Links

SPLIT-TYPE AIR CONDITIONERS
MSZ-LN09VFV
MSZ-LN09VFR
MSZ-LN09VFB
MSZ-LN13VFV
MSZ-LN13VFR
MSZ-LN13VFB
• To use this unit correctly and safely, be sure to read these operating in-
structions before use.
MSZ-LN18VFV
MSZ-LN18VFR
MSZ-LN18VFB
For user
English

Advertisement

loading

Summary of Contents for Mitsubishi Electric MSZ-LN09VFV

  • Page 1 SPLIT-TYPE AIR CONDITIONERS MSZ-LN09VFV MSZ-LN13VFV MSZ-LN18VFV INDOOR UNIT MSZ-LN09VFR MSZ-LN13VFR MSZ-LN18VFR MSZ-LN09VFB MSZ-LN13VFB MSZ-LN18VFB OPERATING INSTRUCTIONS For user English • To use this unit correctly and safely, be sure to read these operating in- structions before use.
  • Page 2: Specifications

    ● OPERATING INSTRUCTIONS ● ONTENTS ■ SAFETY PRECAUTIONS ■ NAME OF EACH PART ■ PREPARATION BEFORE OPERATION ■ MOVE EYE OPERATION ■ SELECTING OPERATION MODES ■ FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT ■ AIRFLOW CONTROL MODE ■ ABSENCE DETECTION ■ I-SAVE OPERATION ■...
  • Page 3 AFETY PRECAUTIONS Do not insert your fi nger, a stick, or other objects into the air inlet Before cleaning the unit, switch it OFF and disconnect the power plug or outlet. or turn the breaker OFF. • This may cause injury, since the fan inside rotates at high speeds during •...
  • Page 4: Indoor Unit

    ● OPERATING INSTRUCTIONS ● AME OF EACH PART Indoor unit Remote controller D.S.PLASMA Battery replacement indicator Signal transmitting Page 4 Air inlet device Page 10, 14 Front panel section Operation dis- Distance of signal : play section Air fi lter About 6 m Beep(s) is (are) heard from the indoor unit when the...
  • Page 5 REPARATION BEFORE OPERATION Setting the installation position Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on. Be sure to set the remote controller in accordance with the installed position of Installing the remote controller batteries the indoor unit.
  • Page 6 ● OPERATING INSTRUCTIONS ● OVE EYE OPERATION In the move eye control mode, the room temperature is controlled based on the sensible temperature. Press during COOL, DRY, HEAT and AUTO mode to activate the move eye control mode. • Press gently using a thin instrument. •...
  • Page 7 ELECTING OPERATION MODES AUTO mode (Auto change over) The unit selects the operation mode according to the difference between the room temperature and the set temperature. During AUTO mode, the unit changes mode (COOL↔HEAT) when the room temperature is about 2°C away from the set temperature for more than 15 minutes.
  • Page 8 ● OPERATING INSTRUCTIONS ● AN SPEED AND AIRFLOW DIRECTION ADJUSTMENT Up-down Airflow direction Press to select airfl ow direction. Each press changes airfl ow direction in the following order: (AUTO) (SWING) (AUTO) ..The vane is set to the most effi cient airfl ow direction. COOL/ DRY/FAN: horizontal position.
  • Page 9 IRFLOW CONTROL MODE BSENCE DETECTION Airfl ow Control mode offers air conditioning according to a location of This function automatically changes the operation to No occupancy an occupant in a room detected by move eye sensor. energy-saving mode or No occupancy Auto-OFF mode when nobody is in the room.
  • Page 10 ● OPERATING INSTRUCTIONS ● -SAVE OPERATION CONO COOL OPERATION Swing airfl ow (change of airfl ow) makes you feel cooler than station- ary airfl ow. The set temperature and the airfl ow direction are automatically changed by the microprocessor. It is possible to perform cooling operation with A simplifi...
  • Page 11 IGHT MODE OPERATION . S. PLASMA OPERATION NIGHT MODE changed the brightness of the operation indicator, In the D.S.PLASMA operation, the indoor unit built-in device reduces disables the beep sound and limits the noise level of the outdoor unit. airborne fungi, viruses, mold, and allergens. Press during operation to activate NIGHT mode.
  • Page 12 ● OPERATING INSTRUCTIONS ● OWERFUL OPERATION IMER OPERATION (ON/OFF TIMER) Press during COOL or HEAT mode page 6 Press during operation to set the timer. start POWERFUL operation. (ON timer) : The unit turns ON at the set time. Fan speed : Exclusive speed for POWERFUL mode Horizontal vane : Set position, or downward airflow position during (OFF timer) : The unit turns OFF at the set time.
  • Page 13 EEKLY TIMER OPERATION • A maximum of 4 ON or OFF timers can be set for individual days of the week. • A maximum of 28 ON or OFF timers can be set for a week. Press , and to set ON/OFF, time, and temperature.
  • Page 14 ● OPERATING INSTRUCTIONS ● PERATION LOCK MERGENCY OPERATION When the remote controller cannot be used... Emergency operation can be activated by pressing the emergency operation switch (E.O.SW) on the indoor unit. Each time the E.O.SW is pressed, the operation changes in the following order: Operation indicator lamp Emergency COOL...
  • Page 15: Front Panel

    LEANING Instructions: • Switch off the power supply or turn off the breaker before cleaning. • Do not soak or rinse the horizontal vane. • Be careful not to touch the metal parts with your hands. • Do not use water hotter than 50°C. •...
  • Page 16: Operating Instructions

    ● OPERATING INSTRUCTIONS ● HEN YOU THINK THAT TROUBLE HAS OCCURRED Even if these items are checked, when the unit does not recover from the Symptom Explanation & Check points trouble, stop using the air conditioner and consult your dealer. Remote controller The display on the remote •...
  • Page 17: Installation Place

    HEN THE AIR CONDITIONER IS NOT NSTALLATION PLACE AND GOING TO BE USED FOR A LONG TIME ELECTRICAL WORK Installation place Operate by COOL mode with the highest temperature Avoid installing the air conditioner in the following places. set or FAN mode for 3 to 4 hours. Page 6 •...
  • Page 18 คู  ม ื อ การใช ง าน   สารบั ญ ขŒ อ ควรระวั ง เพื ่ อ ความปลอดภั ย ชื ่ อ ของส‹ ว นประกอบต‹ า งๆ การเตรี ย มตั ว ก‹ อ นใชŒ ง าน การทํ า งานตรวจจั บ อุ ณ หภู ม ิ แ ละการเคลื ่ อ นไหว การเลื...
  • Page 19 ข อ ควรระวั ง เพื ่ อ ความปลอดภั ย ห า มสอดนิ ้ ว กิ ่ ง ไม หรื อ วั ต ถุ อ ื ่ น ๆ เข า ไปในช อ งลมเข า หรื อ ช อ งลมออก ก  อ นท ํ า ความสะอาดเคร ื ่ อ งปร ั บ อากาศ ควรป  ด สว ิ ต ช  แ ละถอดปล ั ๊ ก หร ื อ ส ั บ เบรกเกอร  ล ง •...
  • Page 20 คู  ม ื อ การใช ง าน   ชื ่ อ ของส ว นประกอบต า งๆ เครื ่ อ งภายในบ า น รี โ มทคอนโทรล อุ ป กรณ D.S.PLASMA ไฟแสดงการเปลี ่ ย นแบตเตอรี ่ หนŒ า 4 ส‹ ว นส‹ ง สั ญ ญาณ ช‹...
  • Page 21 การเตรี ย มตั ว ก อ นใช ง าน ก อ นใช ง าน: เสี ย บปลั ๊ ก ไฟเขŒ า กั บ เตŒ า รั บ และ/หรื อ สั บ เบรกเกอร ข ึ ้ น การตั ้ ง ค า ตํ า แหน ง การติ ด ตั ้ ง การใส...
  • Page 22 คู  ม ื อ การใช ง าน   การท ํ า งานตรวจจ ั บ อ ุ ณ หภ ู ม ิ แ ละการเคล ื ่ อ นไหว ในโหมดควบคุ ม อุ ณ หภู ม ิ แ ละการเคลื ่ อ นไหว อุ ณ หภู ม ิ ห Œ อ งจะถู ก ควบคุ ม จากอุ ณ หภู ม ิ ท ี ่ ร ั บ รู Œ ไ ดŒ กด...
  • Page 23 การเลื อ กโหมดการใช ง าน âËÁ´ AUTO (à»ÅÕ è  ¹âËÁ´¡Ò÷í Ò §Ò¹ÍÑ µ â¹ÁÑ µ Ô ) เคร ื ่ อ งจะเล ื อ กโหมดการท ํ า งานตามความแตกต ‹ า งระหว ‹ า งอ ุ ณ หภ ู ม ิ ห Œ อ งก ั บ อ ุ ณ หภ ู ม ิ ท ี ่ ตั...
  • Page 24 คู  ม ื อ การใช ง าน   การปรั บ ทิ ศ ทางและความเร็ ว ของลม ·Ô È ·Ò§ÅÁ¢Ö é ¹ -ŧ กดปุ † ม เพื ่ อ เลื อ กทิ ศ ทางลม เมื ่ อ กดปุ † ม แต‹ ล ะครั ้ ง ทิ...
  • Page 25 โหมดควบคุ ม ทิ ศ ทางลมแอร การตรวจหาบุ ค คล โหมดควบค ุ ม ท ิ ศ ทางลมแอร  จ ะท ํ า การปร ั บ อากาศตามสถานท ี ่ ท ี ่ ม ี ค นอย ู ‹ ใ นห Œ อ งซ ึ ่ ง ตรวจ ฟ...
  • Page 26 คู  ม ื อ การใช ง าน   การทํ า งานแบบ I-SAVE ระบบทํ า ความเย็ น แบบ ECONO COOL ระบบสวิ ง Swing (เปลี ่ ย นทิ ศ ทางลม) ทํ า ใหŒ ร ู Œ ส ึ ก เย็ น สบายมากกว‹ า ทิ ศ ทางลมเป† า คงที ่ อ...
  • Page 27 การทํ า งานแบบโหมด NIGHT การทํ า งานแบบ D.S.PLASMA NIGHT MODE จะเปลี ่ ย นความสว‹ า งของไฟแสดงการทํ า งาน ป ด เสี ย งบิ ๊ ป และจํ า กั ด การทํ า งานของ D.S.PLASMA ซึ ่ ง เปš น อุ ป กรณ ต ิ ด ตั ้ ง ในตั ว เครื ่ อ งภายในบŒ า นจะช‹ ว ยลด ระดั...
  • Page 28 คู  ม ื อ การใช ง าน   ระบบท ํ า ความเย ็ น แบบ POWERFUL การต ั ้ ง เวลาเป  ด / ป  ด เคร ื ่ อ ง (การต ั ้ ง เวลา ON/ O FF) กดปุ...
  • Page 29 การตั ้ ง เวลาการทํ า งานรายสั ป ดาห • สามารถตั ้ ง เวลาเป ด (ON) หรื อ ป ด (OFF) ไดŒ ส ู ง สุ ด 4 ครั ้ ง ในแต‹ ล ะวั น ของสั ป ดาห  • สามารถตั ้ ง เวลาเป ด (ON) หรื อ ป ด (OFF) ไดŒ ส ู ง สุ ด 28 ครั ้ ง ต‹ อ สั ป ดาห กด...
  • Page 30 คู  ม ื อ การใช ง าน   การล ็ อ คการทํ า งาน ระบบการท ํ า งานฉ ุ ก เฉ ิ น เมื ่ อ ไม ส ามารถใช ง านรี โ มทคอนโทรลได … ท‹ า นสามารถใชŒ ร ะบบการทํ า งานฉุ ก เฉิ น ไดŒ โ ดยการกดสวิ ต ช ก ารทํ า งานฉุ ก เฉิ น (E.O.SW) ที ่ เครื...
  • Page 31 การทํ า ความสะอาด คํ า แนะนํ า : คํ า แนะนํ า : • ป ด สวิ ต ช แ หล‹ ง จ‹ า ยไฟ หรื อ สั บ เบรกเกอร ล งก‹ อ นทํ า ความสะอาด • หŒ า มจุ ‹ ม หรื อ ใชŒ น ้ ํ า ลŒ า งบานเกล็ ด ปรั บ ทิ ศ ทางลมขึ ้ น -ลง •...
  • Page 32 คู  ม ื อ การใช ง าน   เมื ่ อ ท า นคิ ด ว า เครื ่ อ งปรั บ อากาศของท า นมี ป  ญ หา อาการ รายละเอี ย ดและจุ ด ตรวจสอบ หากตรวจสอบทุ ก ข อ แล ว แต ต ั ว เครื ่ อ งยั ง ทํ า งานไม ป กติ ให ห ยุ ด การใช ง านและปรึ ก ษา ตั...
  • Page 33 เมื ่ อ ไม ไ ด ใ ช เ ครื ่ อ งปรั บ อากาศเป น เวลานาน สถานที ่ ต ิ ด ตั ้ ง และงานทางด า นไฟฟ า สถานที ่ ต ิ ด ตั ้ ง สถานที ่ ต ิ ด ตั ้ ง ทํ...
  • Page 36 HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN JG79Y185H01...