Grounding expansion units

If only one expansion unit is being used, go to Step 6, "Installing the power
cables".
If two or more expansion units are being used continue with the following.
Using the grounding kit, fasten the lug at one end of the 0.25m grounding cable to
one of the two threaded inserts (adjacent to the power supply receptacles as
indicated by a ground symbol) at the back of the expansion unit using the M5 x
0.5-inch screw.
If additional expansion units need to be grounded, continue attaching the
grounding cables from unit to unit, overlaying the hole on one end of the
grounding cable from one to the next.