Welcome to your new
Sentry Lithium LiFePO4 Battery.
Please read the instructions and warning on
this card carefully to ensure you get the most
out of your battery.
Warnings
• Keep battery away from exposure to heat,
high voltage and direct sunlight.
• Never short circuit the positive and
negative terminals.
• Never ship or store battery along with
metal.
• Never disassemble the battery.
• Never knock, throw or impact the battery.
• Never throw the battery into water.
• Never install in under bonnet applications.
Tips
• If battery cuts out on low voltage
immediately disconnect load – Low voltage
cut off device strongly recommended at
9.5V.
• If battery gets below 9V, charge battery
within 15 days.
• Battery should be charged every 6 months.
• Ideal storage temperature -20
• Do not leave battery in low state of charge
for long periods of time.
• Keep battery away from high temperatures
• If battery shows signs of deformation, heat
or emits smell, immediately discontinue use.
Charging
A standard Constant Voltage (Automatic)
SLA Battery charger can be used to charge
the Sentry Lithium batteries however the
following requirements must be met:
•
Charger must not contain Sulphation/
Equalisation setting. If so then this step
needs to be turned off.
• Maximum charge voltage of 14.6V
• Recommended float charge voltage 13.9
+/- 0.1V.
• It is not recommended to have batteries sit
on float charge for an extended period of
time.
• Please ensure your charger is matched
to the current rating of your battery and
take note of the recommended charge
current in the batteries specification sheet
– Normally half the batteries rated capacity.
For example SNL12V100S – Recommended
charge current = 50A.
C – 35
C
o
o
• A charger with LiFePO4 setting is
recommended.