Solutions for common problems that may occur with the HDU-409 in
PG-Flex applications are listed in
Table 10. Fault Isolation Guide for PG-Flex
Problem
Solution
LED does
1 Verify that the PG-Flex COLU is installed and operational in the CO.
not light
2 Verify proper cabling between the doubler enclosure and the CO.
3 Measure 150 Vdc between pins 5 or 6 and/or 9 of the HDU. This voltage
peaks every two minutes during the HDSL startup cycle. If less than 100
Vdc is present, check the cabling between the doubler enclosure and
PG-Flex COT shelf. Refer to the COLU practice and verify the COLU is
operating properly.
LED
Synchronization is being attempted with the upstream unit.
continues to
flash green
once a
second
HDU-409
1 The COLU at the CO is not present or is not operating properly.
loses power
2 Check the cabling between the doubler housing and the PG-Flex COT
shelf. Measure the resistance of the HDSL input loop. Resistance should
be normal loop resistance plus the 25 signature of the COLU.
HDSL line
With PG-Flex the GFD is in the COT line unit. Tip or ring ground faults
power only
between the COT and the doubler causes the power to turn on for a few
appears in
seconds every two minutes. With the HDU-409 doubler, a ground fault after
very short
the doubler on Loop 2 has the same affect. On Loop 1, however, the DC
bursts
power does not shut off because of a ground fault. When there is a ground
fault on Loop 1, the doubler limits its output voltage to approximately -40V.
Pair 2 maintains the normal 130V. This is enough voltage to power the
doubler, but not the RT. Typically the HDSL Loop 1, after the doubler, will
drop the resync periodically. Note that if the pairs are reversed, the polarity
of the voltages are reversed.
Remove the line units and doublers and check for cable faults.
HDU-409
A grounded pair is being detected by the HDU-409 in Span 2. Remove
shuts off
HDU-409 and check for ground fault in Span 2.
after Span 1
comes up
HDU-409 Lists 1, 2, and 3
I
AULT
SOLATION
April 30, 2003
Table
10.
Appendix C - Ground Faults
31