Optional Operation

Installer Setting - Optional Function Setting

Setting feature for indoor unit when Plasma purification / Electric heater / Dehumidifier /
Elevation grill / Ventilation kit / Auxiliary heater is newly installed, or installed unit is removed.
h Some functions may not be operated and displayed depending on the product type.
22
If pressing
button long for 3
1
seconds, it enters into remote
controller setter setup mode.
- If pressing once shortly, it enters
into user setup mode. Please press
more than 3 seconds for sure.
If pressing
button repeatedly, it moves to
2
the selected option function code as picture
below.
Select existing condition
3
of each mode by pressing
button.
(00: not installed,
01 : installed)
Function Code
Existing condition
Press
button to save.
4
5
Pressing
button will exit settings mode.
❈ After setup, it automatically gets out of
setup mode if there is no button input for
25 seconds.
❈ When exiting without pressing set button,
the manipulated value is not reflected.
Function
Code
Plasma purification
20
Electric heater
21
Dehumidifier
22
Elevation grill
23
Ventilation kit
24
Auxiliary heater
25