Drain pump and water sensor parts
Before disassembling, remove the connector of each lead
wire from PCB B.
( 4 ) Remove the drain pump assembly
1 Remove the drain piping from the socket of the drain
pump assembly.
2 Unscrew the screws to remove the drain socket cover.
For GUG-01SL-E and GUG-02SL-E
(Seven special screws 4×14, indicated by )
(See the photo below.)
For GUG-03SL-E
(Six special screws 4×14, indicated by )
(See the photo below.)
─ 37 ─
PCB B
Connector for
the drain pump
Connector for
the water sensor
Drain socket cover
Drain socket cover