Electronic Controller Dmc34; How To Switch On The Dryer; How To Switch Off The Dryer; How To Display The Operating Parameters - Beko DRYPOINT RS HP50 NA Series Instructions For Installation And Operation Manual

High pressure compressed air refrigeration dryer
Table of Contents

Advertisement

11.19 Electronic controller DMC34

Set
DISPLAY
The DMC34 displays DewPoint temperature, controls the condenser fan activation, handles a service reminder and keep
record of the total hours of operation of the dryer.

11.19.1 How to switch on the dryer

Power the dryer and switch it on using the ON-OFF switch (pos. 1 paragraph 11.1).
During normal operation the display shows the DewPoint temperature.
The condensate drain test is always active using the button

11.19.2 How to switch off the dryer

Switch it off using the ON-OFF switch (pos. 1 paragraph 11.1).

11.19.3 How to display the operating parameters

During normal operation, the display shows the DewPoint temperature (in °C or °F).
Set
Press and hold
Press and hold
Set
Press and hold
NOTE :
with led
pressure in psig.
The total hours of operation and the hours until the next service are shown in the field 0...999 hours and
in thousands of hours from 01.0 hours on (example : if the display shows number 35 it means 35 hours; if
the display shows number 3.5 it means 3500 hours).

11.19.4 How a service warning / alarm is displayed

A service warning / alarm is an unusual event that must recall the attention of the operators/maintenance technicians. It
does not stop the dryer.
When a service warning / alarm is active, the
Service warnings / alarms are automatically reset as soon as the problem is solved and dryer is powered again.
Scheduled Service reminder requires manual reset.
NOTE: the operator/maintenance technician must inspect the dryer and verify/solve the problem that generated
the service warning.
Service Warning / Alarm
flashing +
flashing +
flashing +
flashing +
flashing +
DRYPOINT® RS 15-550 HP50 NA
button to display condensing pressure.
button to display hours until the next service.
+
buttons to display total hours of operation of the dryer (cannot be reset).
on temperatures are in °C and pressure in barg; with led
led is lighted or flashing.
PF1 - Probe 1 Failure : failure temperature probe BT1
on display
PF2 - Probe 2 Failure : failure pressure probe BP2
on display
HdP - High DewPoint: DewPoint too high
on display
Set BT1>HdS, delay Hdd / Reset BT1<HdS-1°C (HdS-2°F)
LdP - Low DewPoint : DewPoint too low
on display
Set BT1< -1°C (30°F), delay 5 minutes / Reset T1> 1°C (34°F)
SrV - Service : maintenance service time expired SrV
on display
Led - Temperature in °C
Led - Temperature in °F
Led – Drain ON
Led – Fan ON
Led – Alarm/Service
Button – Setup menu access /
Set
Condensing
Button – Decrease / Service
Button – Increase / Drain test
.
on temperatures are in °F and
Description
Technical description
29

Hide quick links:

Advertisement

Table of Contents
loading